FabDigitFabDigit

Aluminum 1050 vs 1070A

Aluminum · grade comparison

Aluminum 1050 and 1070A are both aluminum grades. 1050 is the stronger of the two: yield strength 90 MPa (13.1 ksi) against 25 MPa (3.63 ksi) for 1070A, about 3.6 times as much; tensile strength follows at 110 MPa (16 ksi) vs 70 MPa (10.2 ksi). In exchange, 1070A is the more ductile: elongation 40% versus 5% for 1050, and 1050 is harder (30 HB vs 20 HB). On the shop floor, 1050 sits in a lower cost tier (budget, $) than 1070A (standard, $$).

1050Choose it when strength drives the design, or when cost is the deciding factor.

1070AChoose it when the part is bent, formed or impact-loaded.

1050 vs 1070A: properties

10501070A

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Bulk Modulus

75 GPa10.9 Msi
72 GPa10.4 Msi

Tensile Strength (Ultimate)

110 MPa16 ksi
70 MPa10.2 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
25 MPa3.6 ksi

Elongation at Break

5%
40%

Shear Strength

70 MPa10.2 ksi
45 MPa6.5 ksi

Fatigue Strength (Endurance Limit)

42 MPa6.1 ksi
25 MPa3.6 ksi

Hardness, Brinell

30 HB
20 HB

Hardness, Vickers

33 HV
22 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Density

2.71 g/cm³0.1 lb/in³
2.7 g/cm³0.1 lb/in³

Same in both: Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

229 W/m·K132 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Min Service Temperature

-270°C-454 °F
-250°C-418 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 150°C302 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61 % IACS
61.5 % IACS

Electrical Resistivity

2.83×10⁻⁸ Ω·m1.11 µΩ·in
2.8×10⁻⁸ Ω·m1.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.84 V
-0.85 V

Corrosion Resistance

78 / 100
76 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

30%
70%

Weldability

92 / 100
95 / 100

Formability (cold)

85 / 100
98 / 100

Brazeability / Solderability

85 / 100
70 / 100

Polishability

78 / 100
90 / 100

Same in both: Machinability 30 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

1,100 L/kg132 gal/lb
1,200 L/kg144 gal/lb

Typical Recycled Content

20%
5%

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

41 kN·m/kg
26 kN·m/kg

Specific Stiffness (E / density)

25.5 MN·m/kg
25.6 MN·m/kg

Modulus of Resilience

59 kJ/m³
5 kJ/m³

Thermal Diffusivity

94.1 mm²/s
95.1 mm²/s

Thermal Shock Resistance Index

15
10

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale10501070A

Manufacturing and finishing

Capability10501070A
CNC machiningYes—
Sheet metalYes—
Default condition——
Relative cost$ Budget$$ Standard
Min. machined wall0.5 mm—
Best machined surfaceRa 0.8 µm—
Anodizing Type IIYes—
CerakoteYes—
Chem Film (Alodine)Yes—
DLCYes—
E-CoatingYes—
ElectropolishingYes—
Hard Anodize Type III w/ PTFEYes—
Hard Anodizing Type IIIYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—
Powder CoatingYes—

They share 4 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Silver Plating.

1050 vs 1070A — frequently asked

Is 1050 stronger than 1070A?

Yes. 1050 has a typical yield strength of 90 MPa (13.1 ksi) against 25 MPa (3.63 ksi) for 1070A — about 3.6 times as much. Tensile strength is 110 MPa (16 ksi) vs 70 MPa (10.2 ksi).

Which is cheaper, 1050 or 1070A?

1050 is the lower-cost material: it sits in the budget tier ($) while 1070A is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

When should I choose 1050 over 1070A?

Pick 1050 when strength drives the design, or when cost is the deciding factor. Pick 1070A when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1050 and 1070A side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.