FabDigitFabDigit

Titanium Ti-13V-11Cr-3Al-ST vs Ti-13V-11Cr-3Al-STA

Titanium · Ti-13V-11Cr-3Al temper comparison

Ti-13V-11Cr-3Al-ST and Ti-13V-11Cr-3Al-STA are two conditions of the same titanium grade, Ti-13V-11Cr-3Al: ST (solution annealed) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. Ti-13V-11Cr-3Al-STA is the stronger of the two: yield strength 1,170 MPa (170 ksi) against 860 MPa (125 ksi) for Ti-13V-11Cr-3Al-ST, about 36% more; tensile strength follows at 1,220 MPa (177 ksi) vs 930 MPa (135 ksi). In exchange, Ti-13V-11Cr-3Al-ST is the more ductile: elongation 16% versus 8% for Ti-13V-11Cr-3Al-STA, and Ti-13V-11Cr-3Al-STA is harder (380 HB vs 300 HB). Ti-13V-11Cr-3Al-STA is stiffer (112 GPa vs 102 GPa) and Ti-13V-11Cr-3Al-STA runs hotter in service (315°C vs 260°C continuous). On the shop floor, Ti-13V-11Cr-3Al-ST welds better (good vs poor).

Ti-13V-11Cr-3Al-STChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

Ti-13V-11Cr-3Al-STAChoose it when strength drives the design, or when the part sees heat.

Ti-13V-11Cr-3Al-ST vs Ti-13V-11Cr-3Al-STA: properties

Ti-13V-11Cr-3Al-STTi-13V-11Cr-3Al-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

102 GPa14.8 Msi
112 GPa16.2 Msi

Tensile Strength (Ultimate)

930 MPa135 ksi
1,220 MPa177 ksi

Yield Strength (0.2% offset)

860 MPa125 ksi
1,170 MPa170 ksi

Elongation at Break

16%
8%

Reduction in Area

35%
20%

Compressive Strength

880 MPa128 ksi
1,240 MPa180 ksi

Shear Strength

590 MPa85.6 ksi
730 MPa106 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
550 MPa79.8 ksi

Fracture Toughness (K_IC)

85 MPa·√m77.4 ksi·√in
45 MPa·√m41 ksi·√in

Charpy V-Notch Impact (RT)

22 J16.2 ft·lbf
11 J8.1 ft·lbf

Hardness, Brinell

300 HB
380 HB

Hardness, Rockwell C

31 HRC
40 HRC

Hardness, Vickers

315 HV
400 HV

Same in both: Shear Modulus 40 GPa5.8 Msi · Bulk Modulus 95 GPa13.8 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 4.87 g/cm³0.18 lb/in³ · Melting Point (Solidus) 1,427°C2,601 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

260°C500 °F
315°C599 °F

Same in both: Thermal Conductivity 7.8 W/m·K4.5 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9 µm/m·K5 µin/in·°F · Latent Heat of Fusion 320 J/g138 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.2 % IACS · Electrical Resistivity 1.4×10⁻⁶ Ω·m55.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 88 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

16 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
12%

Weldability

55 / 100
30 / 100

Formability (cold)

70 / 100
20 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb · Embodied Carbon (primary production) 45 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleTi-13V-11Cr-3Al

Ti-13V-11Cr-3Al-ST vs Ti-13V-11Cr-3Al-STA — frequently asked

Is Ti-13V-11Cr-3Al-STA stronger than Ti-13V-11Cr-3Al-ST?

Yes. Ti-13V-11Cr-3Al-STA has a typical yield strength of 1,170 MPa (170 ksi) against 860 MPa (125 ksi) for Ti-13V-11Cr-3Al-ST — about 36% more. Tensile strength is 1,220 MPa (177 ksi) vs 930 MPa (135 ksi).

Which condition does FabDigit quote by default, ST or STA?

ST is the default Ti-13V-11Cr-3Al condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Ti-13V-11Cr-3Al-ST or Ti-13V-11Cr-3Al-STA?

Ti-13V-11Cr-3Al-ST. Its weldability rates good (55/100) against poor (30/100) for Ti-13V-11Cr-3Al-STA.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Ti-13V-11Cr-3Al-ST and Ti-13V-11Cr-3Al-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.