FabDigitFabDigit

Titanium Ti-10-2-3-ST vs Ti-10-2-3 STA-HT

Titanium · Ti-10-2-3 temper comparison

Ti-10-2-3-ST and Ti-10-2-3 STA-HT are two conditions of the same titanium grade, Ti-10-2-3: ST (solution annealed) versus STA-HT (solution treated and aged, high-toughness). The chemistry is identical, so every difference below comes from the condition. Ti-10-2-3 STA-HT is the stronger of the two: yield strength 1,090 MPa (158 ksi) against 840 MPa (122 ksi) for Ti-10-2-3-ST, about 30% more; tensile strength follows at 1,170 MPa (170 ksi) vs 910 MPa (132 ksi). In exchange, Ti-10-2-3-ST is the more ductile: elongation 18% versus 10% for Ti-10-2-3 STA-HT, and Ti-10-2-3 STA-HT is harder (38 HRC vs 29 HRC). Ti-10-2-3 STA-HT is stiffer (112 GPa vs 105 GPa).

Ti-10-2-3-STChoose it when the part is bent, formed or impact-loaded.

Ti-10-2-3 STA-HTChoose it when strength drives the design.

Ti-10-2-3-ST vs Ti-10-2-3 STA-HT: properties

Ti-10-2-3-STTi-10-2-3 STA-HT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

105 GPa15.2 Msi
112 GPa16.2 Msi

Tensile Strength (Ultimate)

910 MPa132 ksi
1,170 MPa170 ksi

Yield Strength (0.2% offset)

840 MPa122 ksi
1,090 MPa158 ksi

Elongation at Break

18%
10%

Reduction in Area

40%
25%

Compressive Strength

1,000 MPa145 ksi
1,180 MPa171 ksi

Shear Strength

620 MPa89.9 ksi
700 MPa102 ksi

Fatigue Strength (Endurance Limit)

480 MPa69.6 ksi
570 MPa82.7 ksi

Fracture Toughness (K_IC)

95 MPa·√m86.5 ksi·√in
72 MPa·√m65.5 ksi·√in

Hardness, Rockwell C

29 HRC
38 HRC

Hardness, Vickers

290 HV
370 HV

Same in both: Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 104 GPa15.1 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 4.65 g/cm³0.17 lb/in³ · Melting Point (Solidus) 1,600°C2,912 °F · Liquidus Temperature 1,650°C3,002 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

7.8 W/m·K4.5 BTU/hr·ft·°F
7.5 W/m·K4.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
315°C599 °F

Same in both: Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9 µm/m·K5 µin/in·°F · Latent Heat of Fusion 365 J/g157 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.2 % IACS · Electrical Resistivity 1.4×10⁻⁶ Ω·m55.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
16 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
16%

Weldability

40 / 100
32 / 100

Formability (cold)

45 / 100
15 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb · Embodied Carbon (primary production) 40 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleTi-10-2-3

Ti-10-2-3-ST vs Ti-10-2-3 STA-HT — frequently asked

Is Ti-10-2-3 STA-HT stronger than Ti-10-2-3-ST?

Yes. Ti-10-2-3 STA-HT has a typical yield strength of 1,090 MPa (158 ksi) against 840 MPa (122 ksi) for Ti-10-2-3-ST — about 30% more. Tensile strength is 1,170 MPa (170 ksi) vs 910 MPa (132 ksi).

Which condition does FabDigit quote by default, ST or STA-HT?

O is the default Ti-10-2-3 condition in the FabDigit quote flow (neither ST nor STA-HT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Ti-10-2-3-ST or Ti-10-2-3 STA-HT?

Ti-10-2-3-ST, by a small margin. Both rate poor for machinability — 22/100 against 16/100 for Ti-10-2-3 STA-HT; for welding the order is Ti-10-2-3-ST first (fair, 40/100) then Ti-10-2-3 STA-HT (poor, 32/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Ti-10-2-3-ST and Ti-10-2-3 STA-HT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.