Titanium · Ti-10-2-3 temper comparison

Ti-10-2-3-O and Ti-10-2-3-STA are two conditions of the same titanium grade, Ti-10-2-3: O (annealed) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. Ti-10-2-3-STA is the stronger of the two: yield strength 1,170 MPa (170 ksi) against 930 MPa (135 ksi) for Ti-10-2-3-O, about 26% more; tensile strength follows at 1,250 MPa (181 ksi) vs 1,000 MPa (145 ksi). In exchange, Ti-10-2-3-O is the more ductile: elongation 12% versus 8% for Ti-10-2-3-STA, and Ti-10-2-3-STA is harder (40 HRC vs 32 HRC). On the shop floor, Ti-10-2-3-O welds better (fair vs poor).

Ti-10-2-3-OChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

Ti-10-2-3-STAChoose it when strength drives the design.

Ti-10-2-3-O vs Ti-10-2-3-STA: properties

Ti-10-2-3-OTi-10-2-3-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,000 MPa145 ksi
1,250 MPa181 ksi

Yield Strength (0.2% offset)

930 MPa135 ksi
1,170 MPa170 ksi

Elongation at Break

12%
8%

Reduction in Area

25%
20%

Compressive Strength

1,000 MPa145 ksi
1,220 MPa177 ksi

Shear Strength

620 MPa89.9 ksi
750 MPa109 ksi

Fatigue Strength (Endurance Limit)

480 MPa69.6 ksi
600 MPa87 ksi

Fracture Toughness (K_IC)

85 MPa·√m77.4 ksi·√in
60 MPa·√m54.6 ksi·√in

Hardness, Rockwell C

32 HRC
40 HRC

Hardness, Vickers

320 HV
395 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 104 GPa15.1 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 4.65 g/cm³0.17 lb/in³ · Melting Point (Solidus) 1,600°C2,912 °F · Liquidus Temperature 1,650°C3,002 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 7.8 W/m·K4.5 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9 µm/m·K5 µin/in·°F · Latent Heat of Fusion 365 J/g157 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.2 % IACS · Electrical Resistivity 1.4×10⁻⁶ Ω·m55.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
15 / 100

Weldability

40 / 100
30 / 100

Formability (cold)

30 / 100
15 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 18% · Castability 25 / 100 · Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb · Embodied Carbon (primary production) 40 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleTi-10-2-3

Ti-10-2-3-O vs Ti-10-2-3-STA — frequently asked

Is Ti-10-2-3-STA stronger than Ti-10-2-3-O?

Yes. Ti-10-2-3-STA has a typical yield strength of 1,170 MPa (170 ksi) against 930 MPa (135 ksi) for Ti-10-2-3-O — about 26% more. Tensile strength is 1,250 MPa (181 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, O or STA?

O is the default Ti-10-2-3 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Ti-10-2-3-O or Ti-10-2-3-STA?

Ti-10-2-3-O, by a small margin. Both rate poor for machinability — 20/100 against 15/100 for Ti-10-2-3-STA; for welding the order is Ti-10-2-3-O first (fair, 40/100) then Ti-10-2-3-STA (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Ti-10-2-3-O and Ti-10-2-3-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.