FabDigitFabDigit

Titanium ERTi-2-ANN vs ERTi-2-AW

Titanium · ERTi-2 temper comparison

ERTi-2-ANN and ERTi-2-AW are two conditions of the same titanium grade, ERTi-2: ANN (annealed) versus AW (as-welded deposit). The chemistry is identical, so every difference below comes from the condition. ERTi-2-AW is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 340 MPa (49.3 ksi) for ERTi-2-ANN, about 12% more; tensile strength follows at 480 MPa (69.6 ksi) vs 450 MPa (65.3 ksi). In exchange, ERTi-2-ANN is the more ductile: elongation 28% versus 22% for ERTi-2-AW, and ERTi-2-AW is harder (155 HB vs 145 HB).

ERTi-2-ANNChoose it when the part is bent, formed or impact-loaded.

ERTi-2-AWChoose it when strength drives the design.

ERTi-2-ANN vs ERTi-2-AW: properties

ERTi-2-ANNERTi-2-AW

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

103 GPa14.9 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

450 MPa65.3 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
380 MPa55.1 ksi

Elongation at Break

28%
22%

Reduction in Area

50%
45%

Compressive Strength

370 MPa53.7 ksi
400 MPa58 ksi

Shear Strength

310 MPa45 ksi
330 MPa47.9 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

145 HB
155 HB

Hardness, Rockwell B

78 HRB
80 HRB

Hardness, Vickers

150 HV
160 HV

Same in both: Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Fatigue Strength (Endurance Limit) 240 MPa34.8 ksi

Physical

Density and transition temperatures.

Same in both: Density 4.51 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,660°C3,020 °F · Liquidus Temperature 1,670°C3,038 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 16.4 W/m·K9.5 BTU/hr·ft·°F · Specific Heat Capacity 523 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8.6 µm/m·K4.8 µin/in·°F · Latent Heat of Fusion 325 J/g140 BTU/lb · Max Service Temperature (continuous) 315°C599 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.6×10⁻⁷ Ω·m22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 92 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

42%
40%

Formability (cold)

75 / 100
70 / 100

Same in both: Weldability 90 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb · Embodied Carbon (primary production) 40 kg CO₂/kg · Embodied Water 800 L/kg95.9 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleERTi-2

ERTi-2-ANN vs ERTi-2-AW — frequently asked

Is ERTi-2-AW stronger than ERTi-2-ANN?

Yes. ERTi-2-AW has a typical yield strength of 380 MPa (55.1 ksi) against 340 MPa (49.3 ksi) for ERTi-2-ANN — about 12% more. Tensile strength is 480 MPa (69.6 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, ANN or AW?

AW is the default ERTi-2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ERTi-2-ANN over ERTi-2-AW?

Pick ERTi-2-ANN when the part is bent, formed or impact-loaded. Pick ERTi-2-AW when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ERTi-2-ANN and ERTi-2-AW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.