FabDigitFabDigit

Steel Y12-CD vs Y12-N

Steel · Y12 temper comparison

Y12-CD and Y12-N are two conditions of the same steel grade, Y12: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. Y12-CD is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 270 MPa (39.2 ksi) for Y12-N, about 67% more; tensile strength follows at 590 MPa (85.6 ksi) vs 440 MPa (63.8 ksi). In exchange, Y12-N is the more ductile: elongation 28% versus 10% for Y12-CD, and Y12-CD is harder (180 HB vs 130 HB). Y12-N runs hotter in service (400°C vs 350°C continuous).

Y12-CDChoose it when strength drives the design.

Y12-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Y12-CD vs Y12-N: properties

Y12-CDY12-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

590 MPa85.6 ksi
440 MPa63.8 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
270 MPa39.2 ksi

Elongation at Break

10%
28%

Reduction in Area

35%
48%

Shear Strength

380 MPa55.1 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
195 MPa28.3 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

180 HB
130 HB

Hardness, Rockwell B

89 HRB
71 HRB

Hardness, Vickers

190 HV
136 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
76 / 100

Machinability Rating (AISI 1212 = 100 %)

100%
90%

Formability (cold)

30 / 100
48 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleY12

Y12-CD vs Y12-N — frequently asked

Is Y12-CD stronger than Y12-N?

Yes. Y12-CD has a typical yield strength of 450 MPa (65.3 ksi) against 270 MPa (39.2 ksi) for Y12-N — about 67% more. Tensile strength is 590 MPa (85.6 ksi) vs 440 MPa (63.8 ksi).

Which condition does FabDigit quote by default, CD or N?

CD is the default Y12 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Y12-CD or Y12-N?

Y12-CD. Its machinability rates excellent (85/100) against very good (76/100) for Y12-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Y12-CD and Y12-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.