FabDigitFabDigit

Steel Y12-A vs Y12-HR

Steel · Y12 temper comparison

Y12-A and Y12-HR are two conditions of the same steel grade, Y12: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. Y12-HR is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 230 MPa (33.4 ksi) for Y12-A, about 13% more; tensile strength follows at 450 MPa (65.3 ksi) vs 400 MPa (58 ksi). In exchange, Y12-A is the more ductile: elongation 30% versus 26% for Y12-HR, and Y12-HR is harder (130 HB vs 115 HB).

Y12-AChoose it when the part is bent, formed or impact-loaded.

Y12-HRChoose it when strength drives the design.

Y12-A vs Y12-HR: properties

Y12-AY12-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
260 MPa37.7 ksi

Elongation at Break

30%
26%

Reduction in Area

50%
45%

Shear Strength

270 MPa39.2 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
200 MPa29 ksi

Hardness, Brinell

115 HB
130 HB

Hardness, Rockwell B

65 HRB
72 HRB

Hardness, Vickers

120 HV
190 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Charpy V-Notch Impact (RT) 30 J22.1 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.5 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
78 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
90%

Formability (cold)

55 / 100
50 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleY12

Y12-A vs Y12-HR — frequently asked

Is Y12-HR stronger than Y12-A?

Yes. Y12-HR has a typical yield strength of 260 MPa (37.7 ksi) against 230 MPa (33.4 ksi) for Y12-A — about 13% more. Tensile strength is 450 MPa (65.3 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, A or HR?

CD is the default Y12 condition in the FabDigit quote flow (neither A nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Y12-A or Y12-HR?

Y12-HR, by a small margin. Both rate very good for machinability — 78/100 against 72/100 for Y12-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Y12-A and Y12-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.