SNCM220-CD and SNCM220 Normalized are two conditions of the same steel grade, SNCM220: CD (cold drawn) versus Normalized. The chemistry is identical, so every difference below comes from the condition. SNCM220-CD is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 360 MPa (52.2 ksi) for SNCM220 Normalized, about 58% more; tensile strength follows at 680 MPa (98.6 ksi) vs 630 MPa (91.4 ksi). In exchange, SNCM220 Normalized is the more ductile: elongation 26% versus 15% for SNCM220-CD, and SNCM220-CD is harder (200 HB vs 183 HB). SNCM220 Normalized runs hotter in service (400°C vs 350°C continuous).
SNCM220-CDChoose it when strength drives the design.
SNCM220 NormalizedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
SNCM220-CD vs SNCM220 Normalized: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29
Physical
Density and transition temperatures.
Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.6 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -40°C-40 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 8.5 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 40 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
SNCM220-CD vs SNCM220 Normalized — frequently asked
Is SNCM220-CD stronger than SNCM220 Normalized?
Yes. SNCM220-CD has a typical yield strength of 570 MPa (82.7 ksi) against 360 MPa (52.2 ksi) for SNCM220 Normalized — about 58% more. Tensile strength is 680 MPa (98.6 ksi) vs 630 MPa (91.4 ksi).
Which condition does FabDigit quote by default, CD or Normalized?
HR is the default SNCM220 condition in the FabDigit quote flow (neither CD nor Normalized). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, SNCM220-CD or SNCM220 Normalized?
SNCM220-CD, by a small margin. Both rate good for machinability — 60/100 against 55/100 for SNCM220 Normalized; for welding the order is SNCM220 Normalized first (good, 55/100) then SNCM220-CD (fair, 50/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in SNCM220-CD and SNCM220 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.