Steel · SK5 temper comparison

SK5 Annealed and SK5-CR are two conditions of the same steel grade, SK5: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. SK5-CR is the stronger of the two: yield strength 430 MPa (62.4 ksi) against 380 MPa (55.1 ksi) for SK5 Annealed, about 13% more; tensile strength follows at 720 MPa (104 ksi) vs 640 MPa (92.8 ksi). In exchange, SK5 Annealed is the more ductile: elongation 20% versus 10% for SK5-CR, and SK5-CR is harder (210 HB vs 185 HB). SK5 Annealed runs hotter in service (400°C vs 350°C continuous).

SK5 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

SK5-CRChoose it when strength drives the design.

SK5 Annealed vs SK5-CR: properties

SK5 AnnealedSK5-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

640 MPa92.8 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
430 MPa62.4 ksi

Elongation at Break

20%
10%

Reduction in Area

35%
20%

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
330 MPa47.9 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
45 MPa·√m41 ksi·√in

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

185 HB
210 HB

Hardness, Rockwell B

90 HRB
95 HRB

Hardness, Vickers

195 HV
220 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 720 MPa104 ksi · Shear Strength 460 MPa66.7 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.82 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
36 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Formability (cold)

45 / 100
40 / 100

Polishability

70 / 100
75 / 100

Same in both: Weldability 18 / 100 · Castability 30 / 100 · Brazeability / Solderability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSK5

SK5 Annealed vs SK5-CR — frequently asked

Is SK5-CR stronger than SK5 Annealed?

Yes. SK5-CR has a typical yield strength of 430 MPa (62.4 ksi) against 380 MPa (55.1 ksi) for SK5 Annealed — about 13% more. Tensile strength is 720 MPa (104 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default SK5 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SK5 Annealed or SK5-CR?

SK5 Annealed, by a small margin. Both rate fair for machinability — 42/100 against 36/100 for SK5-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SK5 Annealed and SK5-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.