FabDigitFabDigit

Steel S45C-CD vs S45C Normalized

Steel · S45C temper comparison

S45C-CD and S45C Normalized are two conditions of the same steel grade, S45C: CD (cold drawn) versus Normalized. The chemistry is identical, so every difference below comes from the condition. S45C-CD is the stronger of the two: yield strength 600 MPa (87 ksi) against 380 MPa (55.1 ksi) for S45C Normalized, about 58% more; tensile strength follows at 700 MPa (102 ksi) vs 620 MPa (89.9 ksi). In exchange, S45C Normalized is the more ductile: elongation 20% versus 12% for S45C-CD, and S45C-CD is harder (207 HB vs 187 HB).

S45C-CDChoose it when strength drives the design.

S45C NormalizedChoose it when the part is bent, formed or impact-loaded.

S45C-CD vs S45C Normalized: properties

S45C-CDS45C Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
380 MPa55.1 ksi

Elongation at Break

12%
20%

Reduction in Area

35%
45%

Shear Strength

420 MPa60.9 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
275 MPa39.9 ksi

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

207 HB
187 HB

Hardness, Rockwell B

94 HRB
90 HRB

Hardness, Vickers

217 HV
196 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 50 MPa·√m45.5 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.7 % IACS · Electrical Resistivity 1.62×10⁻⁷ Ω·m6.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
57%

Weldability

40 / 100
45 / 100

Formability (cold)

25 / 100
40 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS45C

S45C-CD vs S45C Normalized — frequently asked

Is S45C-CD stronger than S45C Normalized?

Yes. S45C-CD has a typical yield strength of 600 MPa (87 ksi) against 380 MPa (55.1 ksi) for S45C Normalized — about 58% more. Tensile strength is 700 MPa (102 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, CD or Normalized?

Normalized is the default S45C condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, S45C-CD or S45C Normalized?

S45C Normalized. Its weldability rates fair (45/100) against fair (40/100) for S45C-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S45C-CD and S45C Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.