FabDigitFabDigit

Steel S45C Normalized vs S45C-QT

Steel · S45C temper comparison

S45C Normalized and S45C-QT are two conditions of the same steel grade, S45C: Normalized versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. S45C-QT is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 380 MPa (55.1 ksi) for S45C Normalized, about 45% more; tensile strength follows at 750 MPa (109 ksi) vs 620 MPa (89.9 ksi). In exchange, S45C Normalized is the more ductile: elongation 20% versus 18% for S45C-QT, and S45C-QT is harder (235 HB vs 187 HB). On the shop floor, S45C Normalized welds better (45 vs 35 out of 100).

S45C NormalizedChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

S45C-QTChoose it when strength drives the design.

S45C Normalized vs S45C-QT: properties

S45C NormalizedS45C-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
750 MPa109 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
550 MPa79.8 ksi

Elongation at Break

20%
18%

Reduction in Area

45%
48%

Shear Strength

380 MPa55.1 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

275 MPa39.9 ksi
340 MPa49.3 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

187 HB
235 HB

Hardness, Vickers

196 HV
248 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 380 MPa55.1 ksi · Hardness, Rockwell B 90 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.7 % IACS · Electrical Resistivity 1.62×10⁻⁷ Ω·m6.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

57%
55%

Weldability

45 / 100
35 / 100

Formability (cold)

40 / 100
25 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS45C

S45C Normalized vs S45C-QT — frequently asked

Is S45C-QT stronger than S45C Normalized?

Yes. S45C-QT has a typical yield strength of 550 MPa (79.8 ksi) against 380 MPa (55.1 ksi) for S45C Normalized — about 45% more. Tensile strength is 750 MPa (109 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, Normalized or QT?

Normalized is the default S45C condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, S45C Normalized or S45C-QT?

S45C Normalized. Its weldability rates fair (45/100) against fair (35/100) for S45C-QT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S45C Normalized and S45C-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.