FabDigitFabDigit

Steel S45C-A vs S45C-CD

Steel · S45C temper comparison

S45C-A and S45C-CD are two conditions of the same steel grade, S45C: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. S45C-CD is the stronger of the two: yield strength 600 MPa (87 ksi) against 310 MPa (45 ksi) for S45C-A, about 94% more; tensile strength follows at 700 MPa (102 ksi) vs 570 MPa (82.7 ksi). In exchange, S45C-A is the more ductile: elongation 24% versus 12% for S45C-CD, and S45C-CD is harder (207 HB vs 163 HB). On the shop floor, S45C-A welds better (50 vs 40 out of 100).

S45C-AChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

S45C-CDChoose it when strength drives the design.

S45C-A vs S45C-CD: properties

S45C-AS45C-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
600 MPa87 ksi

Elongation at Break

24%
12%

Reduction in Area

50%
35%

Shear Strength

380 MPa55.1 ksi
420 MPa60.9 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
16 J11.8 ft·lbf

Hardness, Brinell

163 HB
207 HB

Hardness, Rockwell B

84 HRB
94 HRB

Hardness, Vickers

196 HV
217 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 50 MPa·√m45.5 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.7 % IACS · Electrical Resistivity 1.62×10⁻⁷ Ω·m6.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

56 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
62%

Weldability

50 / 100
40 / 100

Formability (cold)

50 / 100
25 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS45C

S45C-A vs S45C-CD — frequently asked

Is S45C-CD stronger than S45C-A?

Yes. S45C-CD has a typical yield strength of 600 MPa (87 ksi) against 310 MPa (45 ksi) for S45C-A — about 94% more. Tensile strength is 700 MPa (102 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, A or CD?

Normalized is the default S45C condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S45C-A or S45C-CD?

S45C-CD, by a small margin. Both rate good for machinability — 62/100 against 56/100 for S45C-A; for welding the order is S45C-A first (fair, 50/100) then S45C-CD (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S45C-A and S45C-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.