P92-HR and P92 Normalized are two conditions of the same steel grade, P92: HR (hot rolled) versus Normalized. The chemistry is identical, so every difference below comes from the condition. P92 Normalized is the stronger of the two: yield strength 900 MPa (131 ksi) against 620 MPa (89.9 ksi) for P92-HR, about 45% more; tensile strength follows at 1,250 MPa (181 ksi) vs 850 MPa (123 ksi). In exchange, P92-HR is the more ductile: elongation 17% versus 12% for P92 Normalized, and P92 Normalized is harder (400 HB vs 280 HB). On the shop floor, P92-HR machines more easily (28 vs 15 out of 100).

P92-HRChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

P92 NormalizedChoose it when strength drives the design.

P92-HR vs P92 Normalized: properties

P92-HRP92 Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

850 MPa123 ksi
1,250 MPa181 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
900 MPa131 ksi

Elongation at Break

17%
12%

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

280 HB
400 HB

Hardness, Rockwell C

29 HRC
43 HRC

Hardness, Vickers

295 HV
420 HV

Same in both: Elastic (Young's) Modulus 216 GPa31.3 Msi · Shear Modulus 84 GPa12.2 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29 · Reduction in Area 50% · Compressive Strength 630 MPa91.4 ksi · Shear Strength 510 MPa74 ksi · Fatigue Strength (Endurance Limit) 385 MPa55.8 ksi · Fracture Toughness (K_IC) 70 MPa·√m63.7 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 27 W/m·K15.6 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.8 % IACS · Electrical Resistivity 6.2×10⁻⁷ Ω·m24.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 28 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
15 / 100

Weldability

30 / 100
25 / 100

Formability (cold)

20 / 100
10 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 32% · Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP92

P92-HR vs P92 Normalized — frequently asked

Is P92 Normalized stronger than P92-HR?

Yes. P92 Normalized has a typical yield strength of 900 MPa (131 ksi) against 620 MPa (89.9 ksi) for P92-HR — about 45% more. Tensile strength is 1,250 MPa (181 ksi) vs 850 MPa (123 ksi).

Which condition does FabDigit quote by default, HR or Normalized?

HR is the default P92 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, P92-HR or P92 Normalized?

P92-HR, by a small margin. Both rate poor for machinability — 28/100 against 15/100 for P92 Normalized; for welding the order is P92-HR first (poor, 30/100) then P92 Normalized (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in P92-HR and P92 Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.