FabDigitFabDigit

Steel P195GH +A vs P195GH +C

Steel · P195GH temper comparison

P195GH +A and P195GH +C are two conditions of the same steel grade, P195GH: +A (annealed) versus +C (cold drawn). The chemistry is identical, so every difference below comes from the condition. P195GH +C is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 205 MPa (29.7 ksi) for P195GH +A, about 80% more; tensile strength follows at 460 MPa (66.7 ksi) vs 350 MPa (50.8 ksi). In exchange, P195GH +A is the more ductile: elongation 34% versus 12% for P195GH +C, and P195GH +C is harder (150 HB vs 100 HB). P195GH +A runs hotter in service (400°C vs 300°C continuous). On the shop floor, P195GH +C machines more easily (good vs fair).

P195GH +AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

P195GH +CChoose it when strength drives the design, or when the part is machined in volume.

P195GH +A vs P195GH +C: properties

P195GH +AP195GH +C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

212 GPa30.7 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

350 MPa50.8 ksi
460 MPa66.7 ksi

Yield Strength (0.2% offset)

205 MPa29.7 ksi
370 MPa53.7 ksi

Elongation at Break

34%
12%

Reduction in Area

68%
45%

Compressive Strength

205 MPa29.7 ksi
370 MPa53.7 ksi

Shear Strength

230 MPa33.4 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
200 MPa29 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
80 MPa·√m72.8 ksi·√in

Charpy V-Notch Impact (RT)

140 J103 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

100 HB
150 HB

Hardness, Rockwell B

55 HRB
80 HRB

Hardness, Vickers

105 HV
157 HV

Same in both: Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,470°C2,678 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Specific Heat Capacity 461 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.2 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
64 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
78%

Weldability

96 / 100
88 / 100

Formability (cold)

94 / 100
55 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP195GH

P195GH +A vs P195GH +C — frequently asked

Is P195GH +C stronger than P195GH +A?

Yes. P195GH +C has a typical yield strength of 370 MPa (53.7 ksi) against 205 MPa (29.7 ksi) for P195GH +A — about 80% more. Tensile strength is 460 MPa (66.7 ksi) vs 350 MPa (50.8 ksi).

Which condition does FabDigit quote by default, +A or +C?

+N is the default P195GH condition in the FabDigit quote flow (neither +A nor +C). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, P195GH +A or P195GH +C?

P195GH +C. Its machinability rates good (64/100) against fair (52/100) for P195GH +A; for welding the order is P195GH +A first (excellent, 96/100) then P195GH +C (excellent, 88/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in P195GH +A and P195GH +C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.