DD11-N and DD11-SP are two conditions of the same steel grade, DD11: N (normalized) versus SP (skin passed / temper rolled). The chemistry is identical, so every difference below comes from the condition. DD11-SP is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 210 MPa (30.5 ksi) for DD11-N, about 19% more; tensile strength follows at 395 MPa (57.3 ksi) vs 360 MPa (52.2 ksi). In exchange, DD11-N is the more ductile: elongation 35% versus 29% for DD11-SP, and DD11-SP is harder (118 HB vs 105 HB).

DD11-NChoose it when the part is bent, formed or impact-loaded.

DD11-SPChoose it when strength drives the design.

DD11-N vs DD11-SP: properties

DD11-NDD11-SP

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

360 MPa52.2 ksi
395 MPa57.3 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
250 MPa36.3 ksi

Elongation at Break

35%
29%

Reduction in Area

64%
56%

Compressive Strength

210 MPa30.5 ksi
250 MPa36.3 ksi

Shear Strength

270 MPa39.2 ksi
295 MPa42.8 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
185 MPa26.8 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
105 MPa·√m95.6 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
36 J26.6 ft·lbf

Hardness, Brinell

105 HB
118 HB

Hardness, Rockwell B

58 HRB
68 HRB

Hardness, Vickers

110 HV
124 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,490°C2,714 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

96 / 100
95 / 100

Formability (cold)

80 / 100
72 / 100

Same in both: Machinability 60 / 100 · Machinability Rating (AISI 1212 = 100 %) 62% · Brazeability / Solderability 75 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleDD11

DD11-N vs DD11-SP — frequently asked

Is DD11-SP stronger than DD11-N?

Yes. DD11-SP has a typical yield strength of 250 MPa (36.3 ksi) against 210 MPa (30.5 ksi) for DD11-N — about 19% more. Tensile strength is 395 MPa (57.3 ksi) vs 360 MPa (52.2 ksi).

Which condition does FabDigit quote by default, N or SP?

HRPO is the default DD11 condition in the FabDigit quote flow (neither N nor SP). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose DD11-N over DD11-SP?

Pick DD11-N when the part is bent, formed or impact-loaded. Pick DD11-SP when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in DD11-N and DD11-SP side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.