FabDigitFabDigit

Steel C12A-AC vs C12A-ANN

Steel · C12A temper comparison

C12A-AC and C12A-ANN are two conditions of the same steel grade, C12A: AC (spheroidize annealed) versus ANN (annealed). The chemistry is identical, so every difference below comes from the condition. C12A-AC is the stronger of the two: yield strength 800 MPa (116 ksi) against 360 MPa (52.2 ksi) for C12A-ANN, about 122% more; tensile strength follows at 1,150 MPa (167 ksi) vs 560 MPa (81.2 ksi). In exchange, C12A-ANN is the more ductile: elongation 26% versus 5% for C12A-AC, and C12A-AC is harder (400 HB vs 175 HB). C12A-ANN runs hotter in service (400°C vs 200°C continuous) and C12A-ANN conducts heat better (27 W/m·K vs 24 W/m·K). On the shop floor, C12A-ANN machines more easily (good vs poor) and C12A-ANN welds better (fair vs not recommended).

C12A-ACChoose it when strength drives the design.

C12A-ANNChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C12A-AC vs C12A-ANN: properties

C12A-ACC12A-ANN

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

216 GPa31.3 Msi
217 GPa31.5 Msi

Tensile Strength (Ultimate)

1,150 MPa167 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

800 MPa116 ksi
360 MPa52.2 ksi

Elongation at Break

5%
26%

Reduction in Area

12%
63%

Compressive Strength

850 MPa123 ksi
360 MPa52.2 ksi

Shear Strength

690 MPa100 ksi
345 MPa50 ksi

Fatigue Strength (Endurance Limit)

430 MPa62.4 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

40 MPa·√m36.4 ksi·√in
155 MPa·√m141 ksi·√in

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

400 HB
175 HB

Hardness, Rockwell C

43 HRC
9 HRC

Hardness, Vickers

425 HV
184 HV

Same in both: Shear Modulus 84 GPa12.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.77 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

24 W/m·K13.9 BTU/hr·ft·°F
27 W/m·K15.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
400°C752 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.6 % IACS
3 % IACS

Electrical Resistivity

6.6×10⁻⁷ Ω·m26 µΩ·in
5.75×10⁻⁷ Ω·m22.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
32 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.52 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

15 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
58%

Weldability

12 / 100
45 / 100

Formability (cold)

2 / 100
18 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 33 MJ/kg14,187 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC12A

C12A-AC vs C12A-ANN — frequently asked

Is C12A-AC stronger than C12A-ANN?

Yes. C12A-AC has a typical yield strength of 800 MPa (116 ksi) against 360 MPa (52.2 ksi) for C12A-ANN — about 122% more. Tensile strength is 1,150 MPa (167 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, AC or ANN?

N+T is the default C12A condition in the FabDigit quote flow (neither AC nor ANN). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C12A-AC or C12A-ANN?

C12A-ANN. Its machinability rates good (55/100) against poor (15/100) for C12A-AC; for welding the order is C12A-ANN first (fair, 45/100) then C12A-AC (not recommended, 12/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C12A-AC and C12A-ANN side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.