FabDigitFabDigit

Steel A606 Type 4-CR vs A606 Type 4-HR

Steel · A606 Type 4 temper comparison

A606 Type 4-CR and A606 Type 4-HR are two conditions of the same steel grade, A606 Type 4: CR (cold rolled) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. A606 Type 4-HR is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 340 MPa (49.3 ksi) for A606 Type 4-CR, about 12% more; tensile strength follows at 510 MPa (74 ksi) vs 480 MPa (69.6 ksi).

A606 Type 4-HRChoose it when strength drives the design.

A606 Type 4-CR vs A606 Type 4-HR: properties

A606 Type 4-CRA606 Type 4-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
510 MPa74 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
380 MPa55.1 ksi

Reduction in Area

58%
55%

Compressive Strength

345 MPa50 ksi
380 MPa55.1 ksi

Shear Strength

330 MPa47.9 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

225 MPa32.6 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

48 J35.4 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

150 HB
155 HB

Hardness, Rockwell B

80 HRB
82 HRB

Hardness, Vickers

158 HV
163 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 26%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 28 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
60%

Formability (cold)

68 / 100
62 / 100

Polishability

55 / 100
45 / 100

Same in both: Weldability 85 / 100 · Brazeability / Solderability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA606 Type 4

A606 Type 4-CR vs A606 Type 4-HR — frequently asked

Is A606 Type 4-HR stronger than A606 Type 4-CR?

Yes. A606 Type 4-HR has a typical yield strength of 380 MPa (55.1 ksi) against 340 MPa (49.3 ksi) for A606 Type 4-CR — about 12% more. Tensile strength is 510 MPa (74 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, CR or HR?

HR is the default A606 Type 4 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A606 Type 4-CR over A606 Type 4-HR?

Pick A606 Type 4-HR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A606 Type 4-CR and A606 Type 4-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.