FabDigitFabDigit

Steel A606 Type 4-CR vs A606 Type 4 HR-AN

Steel · A606 Type 4 temper comparison

A606 Type 4-CR and A606 Type 4 HR-AN are two conditions of the same steel grade, A606 Type 4: CR (cold rolled) versus HR-AN (hot rolled, annealed or normalized). The chemistry is identical, so every difference below comes from the condition. Both yield at about 340 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cold rolled versus hot rolled, annealed or normalized). A606 Type 4 HR-AN is the more ductile: elongation 30% versus 26% for A606 Type 4-CR, and A606 Type 4-CR is harder (150 HB vs 140 HB).

A606 Type 4 HR-ANChoose it when the part is bent, formed or impact-loaded.

A606 Type 4-CR vs A606 Type 4 HR-AN: properties

A606 Type 4-CRA606 Type 4 HR-AN

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
330 MPa47.9 ksi

Elongation at Break

26%
30%

Reduction in Area

58%
62%

Compressive Strength

345 MPa50 ksi
330 MPa47.9 ksi

Shear Strength

330 MPa47.9 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

225 MPa32.6 ksi
220 MPa31.9 ksi

Charpy V-Notch Impact (RT)

48 J35.4 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

150 HB
140 HB

Hardness, Rockwell B

80 HRB
77 HRB

Hardness, Vickers

158 HV
147 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
47 W/m·K27.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 28 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
63 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
65%

Weldability

85 / 100
88 / 100

Formability (cold)

68 / 100
72 / 100

Polishability

55 / 100
45 / 100

Same in both: Brazeability / Solderability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA606 Type 4

A606 Type 4-CR vs A606 Type 4 HR-AN — frequently asked

What is the difference between A606 Type 4-CR and A606 Type 4 HR-AN?

A606 Type 4-CR and A606 Type 4 HR-AN are two conditions of the same steel grade, A606 Type 4: CR (cold rolled) versus HR-AN (hot rolled, annealed or normalized). The chemistry is identical, so every difference below comes from the condition. Both yield at about 340 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cold rolled versus hot rolled, annealed or normalized).

Which condition does FabDigit quote by default, CR or HR-AN?

HR is the default A606 Type 4 condition in the FabDigit quote flow (neither CR nor HR-AN). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A606 Type 4-CR over A606 Type 4 HR-AN?

Pick A606 Type 4 HR-AN when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A606 Type 4-CR and A606 Type 4 HR-AN side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.