FabDigitFabDigit

Steel A321-CD vs A321-HR

Steel · A321 temper comparison

A321-CD and A321-HR are two conditions of the same steel grade, A321: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. A321-CD is the stronger of the two: yield strength 510 MPa (74 ksi) against 305 MPa (44.2 ksi) for A321-HR, about 67% more; tensile strength follows at 600 MPa (87 ksi) vs 550 MPa (79.8 ksi). In exchange, A321-HR is the more ductile: elongation 18% versus 12% for A321-CD, and A321-CD is harder (179 HB vs 163 HB).

A321-CDChoose it when strength drives the design.

A321-HRChoose it when the part is bent, formed or impact-loaded.

A321-CD vs A321-HR: properties

A321-CDA321-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

510 MPa74 ksi
305 MPa44.2 ksi

Elongation at Break

12%
18%

Reduction in Area

35%
40%

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

179 HB
163 HB

Hardness, Rockwell B

89 HRB
84 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 310 MPa45 ksi · Shear Strength 385 MPa55.8 ksi · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in · Hardness, Vickers 172 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 477 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

66 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
60%

Formability (cold)

30 / 100
45 / 100

Same in both: Weldability 48 / 100 · Brazeability / Solderability 65 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 28%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA321

A321-CD vs A321-HR — frequently asked

Is A321-CD stronger than A321-HR?

Yes. A321-CD has a typical yield strength of 510 MPa (74 ksi) against 305 MPa (44.2 ksi) for A321-HR — about 67% more. Tensile strength is 600 MPa (87 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default A321 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A321-CD or A321-HR?

A321-CD, by a small margin. Both rate good for machinability — 66/100 against 58/100 for A321-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A321-CD and A321-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.