A182 F92 N+T+PWHT and A182 F92 Q+T are two conditions of the same steel grade, A182 F92: N+T+PWHT (N+T + simulated post-weld heat treatment) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. A182 F92 Q+T is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 480 MPa (69.6 ksi) for A182 F92 N+T+PWHT, about 17% more; tensile strength follows at 745 MPa (108 ksi) vs 670 MPa (97.2 ksi). In exchange, A182 F92 N+T+PWHT is the more ductile: elongation 24% versus 21% for A182 F92 Q+T, and A182 F92 Q+T is harder (235 HB vs 205 HB).

A182 F92 N+T+PWHTChoose it when the part is bent, formed or impact-loaded.

A182 F92 Q+TChoose it when strength drives the design.

A182 F92 N+T+PWHT vs A182 F92 Q+T: properties

A182 F92 N+T+PWHTA182 F92 Q+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

670 MPa97.2 ksi
745 MPa108 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
560 MPa81.2 ksi

Elongation at Break

24%
21%

Reduction in Area

65%
62%

Compressive Strength

500 MPa72.5 ksi
580 MPa84.1 ksi

Shear Strength

405 MPa58.7 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
365 MPa52.9 ksi

Fracture Toughness (K_IC)

170 MPa·√m155 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
130 J95.9 ft·lbf

Hardness, Brinell

205 HB
235 HB

Hardness, Rockwell C

15 HRC
22 HRC

Hardness, Vickers

215 HV
247 HV

Same in both: Elastic (Young's) Modulus 216 GPa31.3 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

27 W/m·K15.6 BTU/hr·ft·°F
26.5 W/m·K15.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 620°C1,148 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.45 V · Corrosion Resistance 30 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

48%
42%

Weldability

42 / 100
40 / 100

Formability (cold)

28 / 100
22 / 100

Same in both: Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA182 F92

A182 F92 N+T+PWHT vs A182 F92 Q+T — frequently asked

Is A182 F92 Q+T stronger than A182 F92 N+T+PWHT?

Yes. A182 F92 Q+T has a typical yield strength of 560 MPa (81.2 ksi) against 480 MPa (69.6 ksi) for A182 F92 N+T+PWHT — about 17% more. Tensile strength is 745 MPa (108 ksi) vs 670 MPa (97.2 ksi).

Which condition does FabDigit quote by default, N+T+PWHT or Q+T?

N+T is the default A182 F92 condition in the FabDigit quote flow (neither N+T+PWHT nor Q+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A182 F92 N+T+PWHT or A182 F92 Q+T?

A182 F92 N+T+PWHT, by a small margin. Both rate fair for machinability — 42/100 against 35/100 for A182 F92 Q+T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A182 F92 N+T+PWHT and A182 F92 Q+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.