FabDigitFabDigit

Steel A182 F92-AF vs A182 F92 Q+T

Steel · A182 F92 temper comparison

A182 F92-AF and A182 F92 Q+T are two conditions of the same steel grade, A182 F92: AF (as-forged) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. A182 F92-AF is the stronger of the two: yield strength 900 MPa (131 ksi) against 560 MPa (81.2 ksi) for A182 F92 Q+T, about 61% more; tensile strength follows at 1,200 MPa (174 ksi) vs 745 MPa (108 ksi). In exchange, A182 F92 Q+T is the more ductile: elongation 21% versus 10% for A182 F92-AF, and A182 F92-AF is harder (380 HB vs 235 HB). A182 F92 Q+T runs hotter in service (620°C vs 300°C continuous). On the shop floor, A182 F92 Q+T machines more easily (fair vs poor) and A182 F92 Q+T welds better (fair vs poor).

A182 F92-AFChoose it when strength drives the design.

A182 F92 Q+TChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A182 F92-AF vs A182 F92 Q+T: properties

A182 F92-AFA182 F92 Q+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,200 MPa174 ksi
745 MPa108 ksi

Yield Strength (0.2% offset)

900 MPa131 ksi
560 MPa81.2 ksi

Elongation at Break

10%
21%

Reduction in Area

35%
62%

Compressive Strength

1,250 MPa181 ksi
580 MPa84.1 ksi

Shear Strength

720 MPa104 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

480 MPa69.6 ksi
365 MPa52.9 ksi

Fracture Toughness (K_IC)

40 MPa·√m36.4 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
130 J95.9 ft·lbf

Hardness, Brinell

380 HB
235 HB

Hardness, Rockwell C

41 HRC
22 HRC

Hardness, Vickers

400 HV
247 HV

Same in both: Elastic (Young's) Modulus 216 GPa31.3 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

26 W/m·K15 BTU/hr·ft·°F
26.5 W/m·K15.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
620°C1,148 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.7 % IACS
2.9 % IACS

Electrical Resistivity

6.4×10⁻⁷ Ω·m25.2 µΩ·in
6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

28 / 100
30 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.45 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

15 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
42%

Weldability

18 / 100
40 / 100

Formability (cold)

5 / 100
22 / 100

Same in both: Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA182 F92

A182 F92-AF vs A182 F92 Q+T — frequently asked

Is A182 F92-AF stronger than A182 F92 Q+T?

Yes. A182 F92-AF has a typical yield strength of 900 MPa (131 ksi) against 560 MPa (81.2 ksi) for A182 F92 Q+T — about 61% more. Tensile strength is 1,200 MPa (174 ksi) vs 745 MPa (108 ksi).

Which condition does FabDigit quote by default, AF or Q+T?

N+T is the default A182 F92 condition in the FabDigit quote flow (neither AF nor Q+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A182 F92-AF or A182 F92 Q+T?

A182 F92 Q+T. Its machinability rates fair (35/100) against poor (15/100) for A182 F92-AF; for welding the order is A182 F92 Q+T first (fair, 40/100) then A182 F92-AF (poor, 18/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in A182 F92-AF and A182 F92 Q+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.