FabDigitFabDigit

Steel A182 F12 Cl.2 N+T vs A182 F12 Cl.2 Q+T

Steel · A182 F12 Cl.2 temper comparison

A182 F12 Cl.2 N+T and A182 F12 Cl.2 Q+T are two conditions of the same steel grade, A182 F12 Cl.2: N+T (normalized and tempered) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. A182 F12 Cl.2 Q+T is the stronger of the two: yield strength 400 MPa (58 ksi) against 335 MPa (48.6 ksi) for A182 F12 Cl.2 N+T, about 19% more; tensile strength follows at 585 MPa (84.8 ksi) vs 545 MPa (79 ksi). A182 F12 Cl.2 Q+T is harder — 190 HB against 175 HB for A182 F12 Cl.2 N+T — which matters for wear surfaces and threads.

A182 F12 Cl.2 Q+TChoose it when strength drives the design, or when surface hardness matters.

A182 F12 Cl.2 N+T vs A182 F12 Cl.2 Q+T: properties

A182 F12 Cl.2 N+TA182 F12 Cl.2 Q+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

545 MPa79 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

335 MPa48.6 ksi
400 MPa58 ksi

Elongation at Break

26%
24%

Reduction in Area

58%
62%

Compressive Strength

330 MPa47.9 ksi
400 MPa58 ksi

Shear Strength

340 MPa49.3 ksi
365 MPa52.9 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
275 MPa39.9 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
155 MPa·√m141 ksi·√in

Charpy V-Notch Impact (RT)

95 J70.1 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

175 HB
190 HB

Hardness, Rockwell B

88 HRB
91 HRB

Hardness, Vickers

184 HV
200 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

42 W/m·K24.3 BTU/hr·ft·°F
41 W/m·K23.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 550°C1,022 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 16 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
52%

Weldability

62 / 100
58 / 100

Formability (cold)

50 / 100
42 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA182 F12 Cl.2

A182 F12 Cl.2 N+T vs A182 F12 Cl.2 Q+T — frequently asked

Is A182 F12 Cl.2 Q+T stronger than A182 F12 Cl.2 N+T?

Yes. A182 F12 Cl.2 Q+T has a typical yield strength of 400 MPa (58 ksi) against 335 MPa (48.6 ksi) for A182 F12 Cl.2 N+T — about 19% more. Tensile strength is 585 MPa (84.8 ksi) vs 545 MPa (79 ksi).

Which condition does FabDigit quote by default, N+T or Q+T?

N+T is the default A182 F12 Cl.2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A182 F12 Cl.2 N+T or A182 F12 Cl.2 Q+T?

A182 F12 Cl.2 N+T. Its machinability rates good (55/100) against fair (50/100) for A182 F12 Cl.2 Q+T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A182 F12 Cl.2 N+T and A182 F12 Cl.2 Q+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.