FabDigitFabDigit

Steel A182 F12 Cl.2-ANN vs A182 F12 Cl.2 N+T

Steel · A182 F12 Cl.2 temper comparison

A182 F12 Cl.2-ANN and A182 F12 Cl.2 N+T are two conditions of the same steel grade, A182 F12 Cl.2: ANN (annealed) versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. A182 F12 Cl.2 N+T is the stronger of the two: yield strength 335 MPa (48.6 ksi) against 300 MPa (43.5 ksi) for A182 F12 Cl.2-ANN, about 12% more; tensile strength follows at 545 MPa (79 ksi) vs 510 MPa (74 ksi). In exchange, A182 F12 Cl.2-ANN is the more ductile: elongation 29% versus 26% for A182 F12 Cl.2 N+T, and A182 F12 Cl.2 N+T is harder (175 HB vs 155 HB).

A182 F12 Cl.2-ANNChoose it when the part is bent, formed or impact-loaded.

A182 F12 Cl.2 N+TChoose it when strength drives the design.

A182 F12 Cl.2-ANN vs A182 F12 Cl.2 N+T: properties

A182 F12 Cl.2-ANNA182 F12 Cl.2 N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

510 MPa74 ksi
545 MPa79 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
335 MPa48.6 ksi

Elongation at Break

29%
26%

Reduction in Area

62%
58%

Compressive Strength

300 MPa43.5 ksi
330 MPa47.9 ksi

Shear Strength

320 MPa46.4 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

235 MPa34.1 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

140 MPa·√m127 ksi·√in
130 MPa·√m118 ksi·√in

Charpy V-Notch Impact (RT)

85 J62.7 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

155 HB
175 HB

Hardness, Rockwell B

82 HRB
88 HRB

Hardness, Vickers

162 HV
184 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

43 W/m·K24.8 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 550°C1,022 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 16 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
58%

Weldability

65 / 100
62 / 100

Formability (cold)

55 / 100
50 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA182 F12 Cl.2

A182 F12 Cl.2-ANN vs A182 F12 Cl.2 N+T — frequently asked

Is A182 F12 Cl.2 N+T stronger than A182 F12 Cl.2-ANN?

Yes. A182 F12 Cl.2 N+T has a typical yield strength of 335 MPa (48.6 ksi) against 300 MPa (43.5 ksi) for A182 F12 Cl.2-ANN — about 12% more. Tensile strength is 545 MPa (79 ksi) vs 510 MPa (74 ksi).

Which condition does FabDigit quote by default, ANN or N+T?

N+T is the default A182 F12 Cl.2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A182 F12 Cl.2-ANN or A182 F12 Cl.2 N+T?

A182 F12 Cl.2-ANN, by a small margin. Both rate good for machinability — 60/100 against 55/100 for A182 F12 Cl.2 N+T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A182 F12 Cl.2-ANN and A182 F12 Cl.2 N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.