FabDigitFabDigit

Steel 8627-CD vs 8627-HR

Steel · 8627 temper comparison

8627-CD and 8627-HR are two conditions of the same steel grade, 8627: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 8627-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 400 MPa (58 ksi) for 8627-HR, about 55% more; tensile strength follows at 720 MPa (104 ksi) vs 640 MPa (92.8 ksi). In exchange, 8627-HR is the more ductile: elongation 24% versus 15% for 8627-CD, and 8627-CD is harder (217 HB vs 185 HB).

8627-CDChoose it when strength drives the design.

8627-HRChoose it when the part is bent, formed or impact-loaded.

8627-CD vs 8627-HR: properties

8627-CD8627-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
400 MPa58 ksi

Elongation at Break

15%
24%

Reduction in Area

45%
52%

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

217 HB
185 HB

Hardness, Rockwell B

96 HRB
90 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 370 MPa53.7 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
54 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
60%

Weldability

52 / 100
50 / 100

Formability (cold)

35 / 100
55 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale8627

8627-CD vs 8627-HR — frequently asked

Is 8627-CD stronger than 8627-HR?

Yes. 8627-CD has a typical yield strength of 620 MPa (89.9 ksi) against 400 MPa (58 ksi) for 8627-HR — about 55% more. Tensile strength is 720 MPa (104 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, CD or HR?

A is the default 8627 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8627-CD or 8627-HR?

8627-CD. Its machinability rates good (62/100) against fair (54/100) for 8627-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8627-CD and 8627-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.