FabDigitFabDigit

Steel 8627-A vs 8627-QT425

Steel · 8627 temper comparison

8627-A and 8627-QT425 are two conditions of the same steel grade, 8627: A (solution annealed) versus QT425 (Q&T 425 °C). The chemistry is identical, so every difference below comes from the condition. 8627-QT425 is the stronger of the two: yield strength 1,000 MPa (145 ksi) against 380 MPa (55.1 ksi) for 8627-A, about 163% more; tensile strength follows at 1,170 MPa (170 ksi) vs 560 MPa (81.2 ksi). In exchange, 8627-A is the more ductile: elongation 30% versus 14% for 8627-QT425, and 8627-QT425 is harder (352 HB vs 156 HB). On the shop floor, 8627-A machines more easily (good vs fair).

8627-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

8627-QT425Choose it when strength drives the design.

8627-A vs 8627-QT425: properties

8627-A8627-QT425

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
1,170 MPa170 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
1,000 MPa145 ksi

Elongation at Break

30%
14%

Reduction in Area

60%
52%

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
520 MPa75.4 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

156 HB
352 HB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 370 MPa53.7 ksi · Hardness, Rockwell B 82 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
370°C698 °F

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
36 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
40%

Same in both: Weldability 52 / 100 · Formability (cold) 55 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale8627

8627-A vs 8627-QT425 — frequently asked

Is 8627-QT425 stronger than 8627-A?

Yes. 8627-QT425 has a typical yield strength of 1,000 MPa (145 ksi) against 380 MPa (55.1 ksi) for 8627-A — about 163% more. Tensile strength is 1,170 MPa (170 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, A or QT425?

A is the default 8627 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8627-A or 8627-QT425?

8627-A. Its machinability rates good (58/100) against fair (36/100) for 8627-QT425.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8627-A and 8627-QT425 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.