FabDigitFabDigit

Steel 60Si2Mn Cold Drawn vs 60Si2Mn Hardened & Tempered

Steel · 60Si2Mn temper comparison

60Si2Mn Cold Drawn and 60Si2Mn Hardened & Tempered are two conditions of the same steel grade, 60Si2Mn: Cold Drawn versus Hardened & Tempered (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 60Si2Mn Hardened & Tempered is the stronger of the two: yield strength 1,600 MPa (232 ksi) against 800 MPa (116 ksi) for 60Si2Mn Cold Drawn, about 100% more; tensile strength follows at 1,750 MPa (254 ksi) vs 1,000 MPa (145 ksi). In exchange, 60Si2Mn Cold Drawn is the more ductile: elongation 8% versus 6% for 60Si2Mn Hardened & Tempered, and 60Si2Mn Cold Drawn is harder (300 HB vs 255 HB). 60Si2Mn Hardened & Tempered runs hotter in service (250°C vs 200°C continuous). On the shop floor, 60Si2Mn Cold Drawn machines more easily (fair vs not recommended).

60Si2Mn Cold DrawnChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

60Si2Mn Hardened & TemperedChoose it when strength drives the design, or when the part sees heat.

60Si2Mn Cold Drawn vs 60Si2Mn Hardened & Tempered: properties

60Si2Mn Cold Drawn60Si2Mn Hardened & Tempered

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,000 MPa145 ksi
1,750 MPa254 ksi

Yield Strength (0.2% offset)

800 MPa116 ksi
1,600 MPa232 ksi

Elongation at Break

8%
6%

Reduction in Area

25%
22%

Shear Strength

620 MPa89.9 ksi
1,050 MPa152 ksi

Fatigue Strength (Endurance Limit)

430 MPa62.4 ksi
700 MPa102 ksi

Hardness, Brinell

300 HB
255 HB

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29 · Charpy V-Notch Impact (RT) 12 J8.9 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Thermal Conductivity 40 W/m·K23.1 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 3×10⁻⁷ Ω·m11.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
15%

Weldability

18 / 100
10 / 100

Formability (cold)

25 / 100
5 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale60Si2Mn

60Si2Mn Cold Drawn vs 60Si2Mn Hardened & Tempered — frequently asked

Is 60Si2Mn Hardened & Tempered stronger than 60Si2Mn Cold Drawn?

Yes. 60Si2Mn Hardened & Tempered has a typical yield strength of 1,600 MPa (232 ksi) against 800 MPa (116 ksi) for 60Si2Mn Cold Drawn — about 100% more. Tensile strength is 1,750 MPa (254 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, Cold Drawn or Hardened & Tempered?

Annealed is the default 60Si2Mn condition in the FabDigit quote flow (neither Cold Drawn nor Hardened & Tempered). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 60Si2Mn Cold Drawn or 60Si2Mn Hardened & Tempered?

60Si2Mn Cold Drawn. Its machinability rates fair (50/100) against not recommended (12/100) for 60Si2Mn Hardened & Tempered; for welding the order is 60Si2Mn Cold Drawn first (poor, 18/100) then 60Si2Mn Hardened & Tempered (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 60Si2Mn Cold Drawn and 60Si2Mn Hardened & Tempered side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.