FabDigitFabDigit

Steel 4815 Annealed vs 4815-HR

Steel · 4815 temper comparison

4815 Annealed and 4815-HR are two conditions of the same steel grade, 4815: Annealed versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 4815-HR is the stronger of the two: tensile strength 690 MPa (100 ksi) against 640 MPa (92.8 ksi) for 4815 Annealed, about 8% more. In exchange, 4815 Annealed is the more ductile: elongation 27% versus 22% for 4815-HR, and 4815-HR is harder (200 HB vs 187 HB).

4815 AnnealedChoose it when the part is bent, formed or impact-loaded.

4815-HRChoose it when strength drives the design.

4815 Annealed vs 4815-HR: properties

4815 Annealed4815-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

640 MPa92.8 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
420 MPa60.9 ksi

Elongation at Break

27%
22%

Reduction in Area

58%
50%

Compressive Strength

415 MPa60.2 ksi
420 MPa60.9 ksi

Shear Strength

415 MPa60.2 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
310 MPa45 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

187 HB
200 HB

Hardness, Rockwell B

90 HRB
93 HRB

Hardness, Vickers

196 HV
210 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

36 W/m·K20.8 BTU/hr·ft·°F
35 W/m·K20.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 465 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
7.8 % IACS

Electrical Resistivity

2.15×10⁻⁷ Ω·m8.46 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

60 / 100
55 / 100

Formability (cold)

62 / 100
55 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4815

4815 Annealed vs 4815-HR — frequently asked

Is 4815-HR stronger than 4815 Annealed?

Yes. 4815-HR has a typical tensile strength of 690 MPa (100 ksi) against 640 MPa (92.8 ksi) for 4815 Annealed — about 8% more.

Which condition does FabDigit quote by default, Annealed or HR?

HR is the default 4815 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4815 Annealed or 4815-HR?

4815 Annealed. Its machinability rates good (55/100) against fair (50/100) for 4815-HR; for welding the order is 4815 Annealed first (good, 60/100) then 4815-HR (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4815 Annealed and 4815-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.