FabDigitFabDigit

Steel 4815 Annealed vs 4815-CD

Steel · 4815 temper comparison

4815 Annealed and 4815-CD are two conditions of the same steel grade, 4815: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 4815-CD is the stronger of the two: yield strength 655 MPa (95 ksi) against 415 MPa (60.2 ksi) for 4815 Annealed, about 58% more; tensile strength follows at 760 MPa (110 ksi) vs 640 MPa (92.8 ksi). In exchange, 4815 Annealed is the more ductile: elongation 27% versus 15% for 4815-CD, and 4815-CD is harder (223 HB vs 187 HB). 4815 Annealed runs hotter in service (400°C vs 350°C continuous). On the shop floor, 4815 Annealed welds better (good vs fair).

4815 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4815-CDChoose it when strength drives the design.

4815 Annealed vs 4815-CD: properties

4815 Annealed4815-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

640 MPa92.8 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
655 MPa95 ksi

Elongation at Break

27%
15%

Reduction in Area

58%
45%

Compressive Strength

415 MPa60.2 ksi
655 MPa95 ksi

Shear Strength

415 MPa60.2 ksi
490 MPa71.1 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
340 MPa49.3 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

187 HB
223 HB

Hardness, Rockwell B

90 HRB
97 HRB

Hardness, Vickers

196 HV
235 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

36 W/m·K20.8 BTU/hr·ft·°F
35 W/m·K20.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Specific Heat Capacity 465 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
7.8 % IACS

Electrical Resistivity

2.15×10⁻⁷ Ω·m8.46 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
57 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
62%

Weldability

60 / 100
50 / 100

Formability (cold)

62 / 100
40 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4815

4815 Annealed vs 4815-CD — frequently asked

Is 4815-CD stronger than 4815 Annealed?

Yes. 4815-CD has a typical yield strength of 655 MPa (95 ksi) against 415 MPa (60.2 ksi) for 4815 Annealed — about 58% more. Tensile strength is 760 MPa (110 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

HR is the default 4815 condition in the FabDigit quote flow (neither Annealed nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 4815 Annealed or 4815-CD?

4815 Annealed. Its weldability rates good (60/100) against fair (50/100) for 4815-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4815 Annealed and 4815-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.