Steel · 45# temper comparison

45#-A and 45# Normalized are two conditions of the same steel grade, 45#: A (solution annealed) versus Normalized. The chemistry is identical, so every difference below comes from the condition. 45# Normalized is the stronger of the two: yield strength 375 MPa (54.4 ksi) against 340 MPa (49.3 ksi) for 45#-A, about 10% more; tensile strength follows at 630 MPa (91.4 ksi) vs 570 MPa (82.7 ksi). In exchange, 45#-A is the more ductile: elongation 22% versus 18% for 45# Normalized, and 45# Normalized is harder (179 HB vs 163 HB).

45#-AChoose it when the part is bent, formed or impact-loaded.

45# NormalizedChoose it when strength drives the design.

45#-A vs 45# Normalized: properties

45#-A45# Normalized

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
630 MPa91.4 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
375 MPa54.4 ksi

Elongation at Break

22%
18%

Reduction in Area

50%
42%

Shear Strength

400 MPa58 ksi
410 MPa59.5 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
290 MPa42.1 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
62 MPa·√m56.4 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

163 HB
179 HB

Hardness, Rockwell B

84 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 540 MPa78.3 ksi · Hardness, Vickers 188 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
56 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
57%

Weldability

50 / 100
46 / 100

Formability (cold)

50 / 100
38 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale45#

45#-A vs 45# Normalized — frequently asked

Is 45# Normalized stronger than 45#-A?

Yes. 45# Normalized has a typical yield strength of 375 MPa (54.4 ksi) against 340 MPa (49.3 ksi) for 45#-A — about 10% more. Tensile strength is 630 MPa (91.4 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, A or Normalized?

CD is the default 45# condition in the FabDigit quote flow (neither A nor Normalized). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 45#-A over 45# Normalized?

Pick 45#-A when the part is bent, formed or impact-loaded. Pick 45# Normalized when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 45#-A and 45# Normalized side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.