FabDigitFabDigit

Steel 45#-A vs 45#-CD

Steel · 45# temper comparison

45#-A and 45#-CD are two conditions of the same steel grade, 45#: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 45#-CD is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 340 MPa (49.3 ksi) for 45#-A, about 56% more; tensile strength follows at 625 MPa (90.6 ksi) vs 570 MPa (82.7 ksi). In exchange, 45#-A is the more ductile: elongation 22% versus 12% for 45#-CD, and 45#-CD is harder (179 HB vs 163 HB).

45#-AChoose it when the part is bent, formed or impact-loaded.

45#-CDChoose it when strength drives the design.

45#-A vs 45#-CD: properties

45#-A45#-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
625 MPa90.6 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
530 MPa76.9 ksi

Elongation at Break

22%
12%

Reduction in Area

50%
35%

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

163 HB
179 HB

Hardness, Rockwell B

84 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 540 MPa78.3 ksi · Shear Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 60 MPa·√m54.6 ksi·√in · Hardness, Vickers 188 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
56 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
57%

Weldability

50 / 100
44 / 100

Formability (cold)

50 / 100
30 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale45#

45#-A vs 45#-CD — frequently asked

Is 45#-CD stronger than 45#-A?

Yes. 45#-CD has a typical yield strength of 530 MPa (76.9 ksi) against 340 MPa (49.3 ksi) for 45#-A — about 56% more. Tensile strength is 625 MPa (90.6 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, A or CD?

CD is the default 45# condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 45#-A or 45#-CD?

45#-A. Its weldability rates fair (50/100) against fair (44/100) for 45#-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 45#-A and 45#-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.