FabDigitFabDigit

Steel 4140 vs 5130

Steel · grade comparison

Steel 4140 and 5130 are both steel grades. 4140 is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 415 MPa (60.2 ksi) for 5130, about 16% more; tensile strength follows at 690 MPa (100 ksi) vs 635 MPa (92.1 ksi). 4140 is harder — 210 HB against 187 HB for 5130 — which matters for wear surfaces and threads. On the shop floor, 5130 forms better (50 vs 40 out of 100).

4140Choose it when strength drives the design, or when surface hardness matters.

4140 vs 5130: properties

41405130

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
635 MPa92.1 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
415 MPa60.2 ksi

Reduction in Area

50%
55%

Compressive Strength

480 MPa69.6 ksi
415 MPa60.2 ksi

Fatigue Strength (Endurance Limit)

345 MPa50 ksi
300 MPa43.5 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

210 HB
187 HB

Hardness, Rockwell B

94 HRB
90 HRB

Hardness, Vickers

220 HV
196 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 22% · Shear Strength 420 MPa60.9 ksi

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,416°C2,581 °F
1,420°C2,588 °F

Liquidus Temperature

1,483°C2,701 °F
1,500°C2,732 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

42.6 W/m·K24.6 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Specific Heat Capacity

473 J/kg·K0.11 BTU/lb·°F
477 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.3 µm/m·K6.8 µin/in·°F
12.2 µm/m·K6.8 µin/in·°F

Max Service Temperature (continuous)

425°C797 °F
400°C752 °F

Min Service Temperature

-40°C-40 °F
-30°C-22 °F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
8 % IACS

Same in both: Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
65%

Weldability

40 / 100
45 / 100

Formability (cold)

40 / 100
50 / 100

Brazeability / Solderability

55 / 100
60 / 100

Polishability

60 / 100
65 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

32 MJ/kg13,758 BTU/lb
25 MJ/kg10,748 BTU/lb

Embodied Carbon (primary production)

2.2 kg CO₂/kg
1.9 kg CO₂/kg

Embodied Water

55 L/kg6.6 gal/lb
40 L/kg4.8 gal/lb

Same in both: Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

88 kN·m/kg
81 kN·m/kg

Modulus of Resilience

562 kJ/m³
420 kJ/m³

Thermal Diffusivity

11.5 mm²/s
11.8 mm²/s

Thermal Shock Resistance Index

12
11

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale41405130

Manufacturing and finishing

Capability41405130
Casting & forgingYes—
Default conditionHRHR
Relative cost$$ Standard$$ Standard
Min. machined wall0.8 mm0.8 mm
Best machined surfaceRa 1.6 µmRa 1.6 µm

Both are offered for CNC machining and Sheet metal. Both take the same 38 finishes: AlCrN, AlTiN, Black Oxide, CVD Al2O3, CVD TiCN, CVD TiN, Cerakote, Chrome Plating, Copper Plating, CrN, DLC, E-Coating and 26 more.

4140 vs 5130 — frequently asked

Is 4140 stronger than 5130?

Yes. 4140 has a typical yield strength of 480 MPa (69.6 ksi) against 415 MPa (60.2 ksi) for 5130 — about 16% more. Tensile strength is 690 MPa (100 ksi) vs 635 MPa (92.1 ksi).

Which is cheaper, 4140 or 5130?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, 4140 or 5130?

5130. Its weldability rates fair (45/100) against fair (40/100) for 4140.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4140 and 5130 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.