4063-HR and 4063-N are two conditions of the same steel grade, 4063: HR (hot rolled) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 4063-N is the stronger of the two: yield strength 700 MPa (102 ksi) against 540 MPa (78.3 ksi) for 4063-HR, about 30% more; tensile strength follows at 1,100 MPa (160 ksi) vs 950 MPa (138 ksi). 4063-N is harder — 320 HB against 280 HB for 4063-HR — which matters for wear surfaces and threads.

4063-NChoose it when strength drives the design, or when surface hardness matters.

4063-HR vs 4063-N: properties

4063-HR4063-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

950 MPa138 ksi
1,100 MPa160 ksi

Yield Strength (0.2% offset)

540 MPa78.3 ksi
700 MPa102 ksi

Elongation at Break

14%
13%

Shear Strength

570 MPa82.7 ksi
660 MPa95.7 ksi

Fatigue Strength (Endurance Limit)

420 MPa60.9 ksi
480 MPa69.6 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
16 J11.8 ft·lbf

Hardness, Brinell

280 HB
320 HB

Hardness, Rockwell C

28 HRC
34 HRC

Hardness, Vickers

295 HV
335 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 30%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

45 W/m·K26 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.2 % IACS
8 % IACS

Electrical Resistivity

2.1×10⁻⁷ Ω·m8.27 µΩ·in
2.15×10⁻⁷ Ω·m8.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Weldability

20 / 100
18 / 100

Formability (cold)

30 / 100
25 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4063

4063-HR vs 4063-N — frequently asked

Is 4063-N stronger than 4063-HR?

Yes. 4063-N has a typical yield strength of 700 MPa (102 ksi) against 540 MPa (78.3 ksi) for 4063-HR — about 30% more. Tensile strength is 1,100 MPa (160 ksi) vs 950 MPa (138 ksi).

Which condition does FabDigit quote by default, HR or N?

OQT425 is the default 4063 condition in the FabDigit quote flow (neither HR nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4063-HR or 4063-N?

4063-HR, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for 4063-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4063-HR and 4063-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.