FabDigitFabDigit

Steel 4063-CD vs 4063-HR

Steel · 4063 temper comparison

4063-CD and 4063-HR are two conditions of the same steel grade, 4063: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 4063-CD is the stronger of the two: yield strength 860 MPa (125 ksi) against 540 MPa (78.3 ksi) for 4063-HR, about 59% more; tensile strength follows at 1,030 MPa (149 ksi) vs 950 MPa (138 ksi). In exchange, 4063-HR is the more ductile: elongation 14% versus 9% for 4063-CD, and 4063-CD is harder (300 HB vs 280 HB). 4063-HR runs hotter in service (400°C vs 250°C continuous).

4063-CDChoose it when strength drives the design.

4063-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4063-CD vs 4063-HR: properties

4063-CD4063-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,030 MPa149 ksi
950 MPa138 ksi

Yield Strength (0.2% offset)

860 MPa125 ksi
540 MPa78.3 ksi

Elongation at Break

9%
14%

Reduction in Area

28%
30%

Shear Strength

620 MPa89.9 ksi
570 MPa82.7 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
420 MPa60.9 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

300 HB
280 HB

Hardness, Rockwell C

31 HRC
28 HRC

Hardness, Vickers

315 HV
295 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
400°C752 °F

Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
8.2 % IACS

Electrical Resistivity

2.15×10⁻⁷ Ω·m8.46 µΩ·in
2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
45%

Weldability

15 / 100
20 / 100

Formability (cold)

20 / 100
30 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale4063

4063-CD vs 4063-HR — frequently asked

Is 4063-CD stronger than 4063-HR?

Yes. 4063-CD has a typical yield strength of 860 MPa (125 ksi) against 540 MPa (78.3 ksi) for 4063-HR — about 59% more. Tensile strength is 1,030 MPa (149 ksi) vs 950 MPa (138 ksi).

Which condition does FabDigit quote by default, CD or HR?

OQT425 is the default 4063 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4063-CD or 4063-HR?

4063-CD, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 4063-HR; for welding the order is 4063-HR first (poor, 20/100) then 4063-CD (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4063-CD and 4063-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.