FabDigitFabDigit

Steel 4012 vs 4140

Steel · grade comparison

Steel 4012 and 4140 are both steel grades. 4140 is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 330 MPa (47.9 ksi) for 4012, about 45% more; tensile strength follows at 690 MPa (100 ksi) vs 470 MPa (68.2 ksi). In exchange, 4012 is the more ductile: elongation 28% versus 22% for 4140, and 4140 is harder (210 HB vs 137 HB). On the shop floor, 4012 welds better (very good vs fair) and 4012 sits in a lower cost tier (budget, $) than 4140 (standard, $$).

4012Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

4140Choose it when strength drives the design.

4012 vs 4140: properties

40124140

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
480 MPa69.6 ksi

Elongation at Break

28%
22%

Reduction in Area

60%
50%

Shear Strength

330 MPa47.9 ksi
420 MPa60.9 ksi

Fatigue Strength (Endurance Limit)

220 MPa31.9 ksi
345 MPa50 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

137 HB
210 HB

Hardness, Rockwell B

76 HRB
94 HRB

Hardness, Vickers

144 HV
220 HV

Compressive Strength

—
480 MPa69.6 ksi

Fracture Toughness (K_IC)

—
110 MPa·√m100 ksi·√in

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,425°C2,597 °F
1,416°C2,581 °F

Liquidus Temperature

1,510°C2,750 °F
1,483°C2,701 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
42.6 W/m·K24.6 BTU/hr·ft·°F

Specific Heat Capacity

470 J/kg·K0.11 BTU/lb·°F
473 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.2 µm/m·K6.8 µin/in·°F
12.3 µm/m·K6.8 µin/in·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
62%

Weldability

80 / 100
40 / 100

Formability (cold)

72 / 100
40 / 100

Brazeability / Solderability

70 / 100
55 / 100

Polishability

55 / 100
60 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

29 MJ/kg12,468 BTU/lb
32 MJ/kg13,758 BTU/lb

Embodied Carbon (primary production)

2.1 kg CO₂/kg
2.2 kg CO₂/kg

Embodied Water

60 L/kg7.2 gal/lb
55 L/kg6.6 gal/lb

Same in both: Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

60 kN·m/kg
88 kN·m/kg

Modulus of Resilience

266 kJ/m³
562 kJ/m³

Thermal Diffusivity

11.9 mm²/s
11.5 mm²/s

Thermal Shock Resistance Index

8
12

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale41404012

Manufacturing and finishing

Capability40124140
CNC machining—Yes
Sheet metal—Yes
Casting & forging—Yes
Default condition—HR
Relative cost$ Budget$$ Standard
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

4012 vs 4140 — frequently asked

Is 4140 stronger than 4012?

Yes. 4140 has a typical yield strength of 480 MPa (69.6 ksi) against 330 MPa (47.9 ksi) for 4012 — about 45% more. Tensile strength is 690 MPa (100 ksi) vs 470 MPa (68.2 ksi).

Which is cheaper, 4012 or 4140?

4012 is the lower-cost material: it sits in the budget tier ($) while 4140 is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which welds better, 4012 or 4140?

4012. Its weldability rates very good (80/100) against fair (40/100) for 4140.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4012 and 4140 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.