FabDigitFabDigit

Steel 30CrMo-CR vs 30CrMo-HR

Steel · 30CrMo temper comparison

30CrMo-CR and 30CrMo-HR are two conditions of the same steel grade, 30CrMo: CR (cold rolled) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 30CrMo-CR is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 500 MPa (72.5 ksi) for 30CrMo-HR, about 14% more. In exchange, 30CrMo-HR is the more ductile: elongation 18% versus 13% for 30CrMo-CR. 30CrMo-HR runs hotter in service (400°C vs 350°C continuous).

30CrMo-CRChoose it when strength drives the design.

30CrMo-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

30CrMo-CR vs 30CrMo-HR: properties

30CrMo-CR30CrMo-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

570 MPa82.7 ksi
500 MPa72.5 ksi

Elongation at Break

13%
18%

Reduction in Area

40%
45%

Shear Strength

440 MPa63.8 ksi
500 MPa72.5 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
360 MPa52.2 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

225 HB
215 HB

Hardness, Rockwell B

97 HRB
95 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
54 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
58%

Weldability

58 / 100
60 / 100

Formability (cold)

50 / 100
45 / 100

Polishability

72 / 100
65 / 100

Same in both: Brazeability / Solderability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale30CrMo

30CrMo-CR vs 30CrMo-HR — frequently asked

Is 30CrMo-CR stronger than 30CrMo-HR?

Yes. 30CrMo-CR has a typical yield strength of 570 MPa (82.7 ksi) against 500 MPa (72.5 ksi) for 30CrMo-HR — about 14% more. Tensile strength is 720 MPa (104 ksi) vs 800 MPa (116 ksi).

Which condition does FabDigit quote by default, CR or HR?

HR is the default 30CrMo condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 30CrMo-CR over 30CrMo-HR?

Pick 30CrMo-CR when strength drives the design. Pick 30CrMo-HR when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 30CrMo-CR and 30CrMo-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.