FabDigitFabDigit

Steel 30CrMo-CD vs 30CrMo-CR

Steel · 30CrMo temper comparison

30CrMo-CD and 30CrMo-CR are two conditions of the same steel grade, 30CrMo: CD (cold drawn) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 30CrMo-CD is the stronger of the two: yield strength 660 MPa (95.7 ksi) against 570 MPa (82.7 ksi) for 30CrMo-CR, about 16% more; tensile strength follows at 790 MPa (115 ksi) vs 720 MPa (104 ksi). In exchange, 30CrMo-CR is the more ductile: elongation 13% versus 11% for 30CrMo-CD. 30CrMo-CD runs hotter in service (400°C vs 350°C continuous).

30CrMo-CDChoose it when strength drives the design, or when the part sees heat.

30CrMo-CRChoose it when the part is bent, formed or impact-loaded.

30CrMo-CD vs 30CrMo-CR: properties

30CrMo-CD30CrMo-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

790 MPa115 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

660 MPa95.7 ksi
570 MPa82.7 ksi

Elongation at Break

11%
13%

Shear Strength

500 MPa72.5 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

370 MPa53.7 ksi
330 MPa47.9 ksi

Hardness, Brinell

235 HB
225 HB

Hardness, Rockwell B

99 HRB
97 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 40% · Charpy V-Notch Impact (RT) 35 J25.8 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
60%

Weldability

60 / 100
58 / 100

Formability (cold)

30 / 100
50 / 100

Polishability

65 / 100
72 / 100

Same in both: Brazeability / Solderability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale30CrMo

30CrMo-CD vs 30CrMo-CR — frequently asked

Is 30CrMo-CD stronger than 30CrMo-CR?

Yes. 30CrMo-CD has a typical yield strength of 660 MPa (95.7 ksi) against 570 MPa (82.7 ksi) for 30CrMo-CR — about 16% more. Tensile strength is 790 MPa (115 ksi) vs 720 MPa (104 ksi).

Which condition does FabDigit quote by default, CD or CR?

HR is the default 30CrMo condition in the FabDigit quote flow (neither CD nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 30CrMo-CD or 30CrMo-CR?

30CrMo-CD, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 30CrMo-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 30CrMo-CD and 30CrMo-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.