FabDigitFabDigit

Steel 1084 vs A227

Steel · grade comparison

Steel 1084 and A227 are both steel grades. A227 is the stronger of the two: yield strength 1,380 MPa (200 ksi) against 585 MPa (84.8 ksi) for 1084, about 136% more; tensile strength follows at 1,620 MPa (235 ksi) vs 965 MPa (140 ksi). In exchange, 1084 is the more ductile: elongation 12% versus 4% for A227, and A227 is harder (450 HB vs 293 HB). 1084 runs hotter in service (400°C vs 120°C continuous). On the shop floor, 1084 machines more easily (fair vs poor) and A227 sits in a lower cost tier (budget, $) than 1084 (standard, $$).

1084Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A227Choose it when strength drives the design, or when cost is the deciding factor.

1084 vs A227: properties

1084A227

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
200 GPa29 Msi

Shear Modulus

80 GPa11.6 Msi
79.3 GPa11.5 Msi

Tensile Strength (Ultimate)

965 MPa140 ksi
1,620 MPa235 ksi

Yield Strength (0.2% offset)

585 MPa84.8 ksi
1,380 MPa200 ksi

Elongation at Break

12%
4%

Reduction in Area

17%
35%

Shear Strength

580 MPa84.1 ksi
1,000 MPa145 ksi

Fatigue Strength (Endurance Limit)

420 MPa60.9 ksi
600 MPa87 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
—

Hardness, Brinell

293 HB
450 HB

Hardness, Rockwell C

31 HRC
46 HRC

Compressive Strength

—
1,650 MPa239 ksi

Fracture Toughness (K_IC)

—
35 MPa·√m31.9 ksi·√in

Hardness, Vickers

—
470 HV

Same in both: Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Liquidus Temperature

1,470°C2,678 °F
1,480°C2,696 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

48 W/m·K27.7 BTU/hr·ft·°F
47 W/m·K27.2 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

11.3 µm/m·K6.3 µin/in·°F
12.2 µm/m·K6.8 µin/in·°F

Max Service Temperature (continuous)

400°C752 °F
120°C248 °F

Min Service Temperature

-20°C-4 °F
-40°C-40 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Latent Heat of Fusion 250 J/g107 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

9.6 % IACS
9 % IACS

Electrical Resistivity

1.8×10⁻⁷ Ω·m7.09 µΩ·in
1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

8 / 100
10 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
25%

Weldability

20 / 100
15 / 100

Formability (cold)

30 / 100
45 / 100

Brazeability / Solderability

60 / 100
40 / 100

Polishability

75 / 100
50 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

25 MJ/kg10,748 BTU/lb
28 MJ/kg12,038 BTU/lb

Embodied Carbon (primary production)

1.9 kg CO₂/kg
2.1 kg CO₂/kg

Embodied Water

40 L/kg4.8 gal/lb
45 L/kg5.4 gal/lb

Typical Recycled Content

30%
25%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

123 kN·m/kg
206 kN·m/kg

Specific Stiffness (E / density)

26.1 MN·m/kg
25.5 MN·m/kg

Modulus of Resilience

835 kJ/m³
4,761 kJ/m³

Thermal Diffusivity

13 mm²/s
12.7 mm²/s

Thermal Shock Resistance Index

20
31

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1084A227

Manufacturing and finishing

Capability1084A227
CNC machiningYes—
Sheet metalYes—
Default conditionHR—
Relative cost$$ Standard$ Budget
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

1084 vs A227 — frequently asked

Is A227 stronger than 1084?

Yes. A227 has a typical yield strength of 1,380 MPa (200 ksi) against 585 MPa (84.8 ksi) for 1084 — about 136% more. Tensile strength is 1,620 MPa (235 ksi) vs 965 MPa (140 ksi).

Which is cheaper, 1084 or A227?

A227 is the lower-cost material: it sits in the budget tier ($) while 1084 is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 1084 or A227?

1084. Its machinability rates fair (35/100) against poor (25/100) for A227; for welding the order is 1084 first (poor, 20/100) then A227 (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1084 and A227 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.