FabDigitFabDigit

Steel 1065 Annealed vs 1065-CR

Steel · 1065 temper comparison

1065 Annealed and 1065-CR are two conditions of the same steel grade, 1065: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 1065-CR is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 340 MPa (49.3 ksi) for 1065 Annealed, about 53% more; tensile strength follows at 720 MPa (104 ksi) vs 615 MPa (89.2 ksi). In exchange, 1065 Annealed is the more ductile: elongation 23% versus 10% for 1065-CR, and 1065-CR is harder (205 HB vs 174 HB). 1065 Annealed runs hotter in service (350°C vs 250°C continuous).

1065 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1065-CRChoose it when strength drives the design.

1065 Annealed vs 1065-CR: properties

1065 Annealed1065-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

615 MPa89.2 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
520 MPa75.4 ksi

Elongation at Break

23%
10%

Reduction in Area

45%
30%

Compressive Strength

380 MPa55.1 ksi
520 MPa75.4 ksi

Shear Strength

400 MPa58 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
320 MPa46.4 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
42 MPa·√m38.2 ksi·√in

Charpy V-Notch Impact (RT)

15 J11.1 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

174 HB
205 HB

Hardness, Rockwell B

88 HRB
94 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
250°C482 °F

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.3 µm/m·K6.3 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
44 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

25 / 100
22 / 100

Formability (cold)

45 / 100
35 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 30 L/kg3.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1065

1065 Annealed vs 1065-CR — frequently asked

Is 1065-CR stronger than 1065 Annealed?

Yes. 1065-CR has a typical yield strength of 520 MPa (75.4 ksi) against 340 MPa (49.3 ksi) for 1065 Annealed — about 53% more. Tensile strength is 720 MPa (104 ksi) vs 615 MPa (89.2 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default 1065 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1065 Annealed or 1065-CR?

1065 Annealed, by a small margin. Both rate fair for machinability — 50/100 against 44/100 for 1065-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1065 Annealed and 1065-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.