FabDigitFabDigit

Steel 1017-HR vs 1017-N

Steel · 1017 temper comparison

1017-HR and 1017-N are two conditions of the same steel grade, 1017: HR (hot rolled) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1017-N is the stronger of the two: yield strength 285 MPa (41.3 ksi) against 235 MPa (34.1 ksi) for 1017-HR, about 21% more; tensile strength follows at 425 MPa (61.6 ksi) vs 380 MPa (55.1 ksi). 1017-N is the more ductile: elongation 32% versus 26% for 1017-HR, and 1017-N is harder (121 HB vs 111 HB).

1017-NChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1017-HR vs 1017-N: properties

1017-HR1017-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

380 MPa55.1 ksi
425 MPa61.6 ksi

Yield Strength (0.2% offset)

235 MPa34.1 ksi
285 MPa41.3 ksi

Elongation at Break

26%
32%

Reduction in Area

50%
65%

Shear Strength

240 MPa34.8 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

111 HB
121 HB

Hardness, Rockwell B

63 HRB
68 HRB

Hardness, Vickers

116 HV
127 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 370 MPa53.7 ksi · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,525°C2,777 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

47 / 100
51 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
65%

Formability (cold)

80 / 100
78 / 100

Same in both: Weldability 95 / 100 · Brazeability / Solderability 80 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1017

1017-HR vs 1017-N — frequently asked

Is 1017-N stronger than 1017-HR?

Yes. 1017-N has a typical yield strength of 285 MPa (41.3 ksi) against 235 MPa (34.1 ksi) for 1017-HR — about 21% more. Tensile strength is 425 MPa (61.6 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, HR or N?

CD is the default 1017 condition in the FabDigit quote flow (neither HR nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1017-HR over 1017-N?

Pick 1017-N when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1017-HR and 1017-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.