FabDigitFabDigit

Steel 1017-A vs 1017-HR

Steel · 1017 temper comparison

1017-A and 1017-HR are two conditions of the same steel grade, 1017: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1017-HR is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 220 MPa (31.9 ksi) for 1017-A, about 7% more. In exchange, 1017-A is the more ductile: elongation 34% versus 26% for 1017-HR, and 1017-HR is harder (111 HB vs 105 HB).

1017-AChoose it when the part is bent, formed or impact-loaded.

1017-HRChoose it when strength drives the design.

1017-A vs 1017-HR: properties

1017-A1017-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

365 MPa52.9 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

220 MPa31.9 ksi
235 MPa34.1 ksi

Elongation at Break

34%
26%

Reduction in Area

65%
50%

Shear Strength

230 MPa33.4 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
185 MPa26.8 ksi

Charpy V-Notch Impact (RT)

95 J70.1 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

105 HB
111 HB

Hardness, Rockwell B

59 HRB
63 HRB

Hardness, Vickers

110 HV
116 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 370 MPa53.7 ksi · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,525°C2,777 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

43 / 100
47 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
60%

Formability (cold)

90 / 100
80 / 100

Same in both: Weldability 95 / 100 · Brazeability / Solderability 80 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1017

1017-A vs 1017-HR — frequently asked

Is 1017-HR stronger than 1017-A?

Yes. 1017-HR has a typical yield strength of 235 MPa (34.1 ksi) against 220 MPa (31.9 ksi) for 1017-A — about 7% more. Tensile strength is 380 MPa (55.1 ksi) vs 365 MPa (52.9 ksi).

Which condition does FabDigit quote by default, A or HR?

CD is the default 1017 condition in the FabDigit quote flow (neither A nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1017-A over 1017-HR?

Pick 1017-A when the part is bent, formed or impact-loaded. Pick 1017-HR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1017-A and 1017-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.