FabDigitFabDigit

Steel 1005-CD vs 1005-N

Steel · 1005 temper comparison

1005-CD and 1005-N are two conditions of the same steel grade, 1005: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1005-CD is the stronger of the two: yield strength 315 MPa (45.7 ksi) against 190 MPa (27.6 ksi) for 1005-N, about 66% more; tensile strength follows at 365 MPa (52.9 ksi) vs 310 MPa (45 ksi). In exchange, 1005-N is the more ductile: elongation 33% versus 20% for 1005-CD, and 1005-CD is harder (105 HB vs 90 HB).

1005-CDChoose it when strength drives the design.

1005-NChoose it when the part is bent, formed or impact-loaded.

1005-CD vs 1005-N: properties

1005-CD1005-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

365 MPa52.9 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

315 MPa45.7 ksi
190 MPa27.6 ksi

Elongation at Break

20%
33%

Reduction in Area

55%
62%

Compressive Strength

315 MPa45.7 ksi
190 MPa27.6 ksi

Shear Strength

220 MPa31.9 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
150 MPa21.8 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
140 J103 ft·lbf

Hardness, Brinell

105 HB
90 HB

Hardness, Rockwell B

60 HRB
48 HRB

Hardness, Vickers

110 HV
95 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,530°C2,786 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 481 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
12 % IACS

Electrical Resistivity

1.59×10⁻⁷ Ω·m6.26 µΩ·in
1.45×10⁻⁷ Ω·m5.71 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
48%

Weldability

95 / 100
97 / 100

Formability (cold)

80 / 100
98 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1005

1005-CD vs 1005-N — frequently asked

Is 1005-CD stronger than 1005-N?

Yes. 1005-CD has a typical yield strength of 315 MPa (45.7 ksi) against 190 MPa (27.6 ksi) for 1005-N — about 66% more. Tensile strength is 365 MPa (52.9 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, CD or N?

CD is the default 1005 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1005-CD over 1005-N?

Pick 1005-CD when strength drives the design. Pick 1005-N when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1005-CD and 1005-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.