FabDigitFabDigit

Stainless Steel V-57-ST vs V-57 STA-900

Stainless Steel · V-57 temper comparison

V-57-ST and V-57 STA-900 are two conditions of the same stainless steel grade, V-57: ST (solution annealed) versus STA-900 (solution treated ~900 °C (1650 °F) + aged 720 °C/16 h). The chemistry is identical, so every difference below comes from the condition. V-57 STA-900 is the stronger of the two: yield strength 795 MPa (115 ksi) against 275 MPa (39.9 ksi) for V-57-ST, about 189% more; tensile strength follows at 1,140 MPa (165 ksi) vs 690 MPa (100 ksi). In exchange, V-57-ST is the more ductile: elongation 45% versus 18% for V-57 STA-900, and V-57 STA-900 is harder (321 HB vs 170 HB). V-57 STA-900 runs hotter in service (595°C vs 540°C continuous). On the shop floor, V-57-ST welds better (good vs fair).

V-57-STChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

V-57 STA-900Choose it when strength drives the design, or when the part sees heat.

V-57-ST vs V-57 STA-900: properties

V-57-STV-57 STA-900

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
1,140 MPa165 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
795 MPa115 ksi

Elongation at Break

45%
18%

Reduction in Area

55%
28%

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
480 MPa69.6 ksi

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
32 J23.6 ft·lbf

Hardness, Brinell

170 HB
321 HB

Hardness, Rockwell C

32 HRC
34 HRC

Same in both: Elastic (Young's) Modulus 201 GPa29.2 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.31 · Compressive Strength 745 MPa108 ksi · Shear Strength 655 MPa95 ksi · Fracture Toughness (K_IC) 130 MPa·√m118 ksi·√in · Hardness, Vickers 320 HV

Physical

Density and transition temperatures.

Same in both: Density 7.92 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

540°C1,004 °F
595°C1,103 °F

Same in both: Thermal Conductivity 14 W/m·K8.1 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.5 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.9 % IACS · Electrical Resistivity 9.1×10⁻⁷ Ω·m35.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
15%

Weldability

55 / 100
40 / 100

Formability (cold)

60 / 100
25 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.8 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleV-57

V-57-ST vs V-57 STA-900 — frequently asked

Is V-57 STA-900 stronger than V-57-ST?

Yes. V-57 STA-900 has a typical yield strength of 795 MPa (115 ksi) against 275 MPa (39.9 ksi) for V-57-ST — about 189% more. Tensile strength is 1,140 MPa (165 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, ST or STA-900?

STA is the default V-57 condition in the FabDigit quote flow (neither ST nor STA-900). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, V-57-ST or V-57 STA-900?

V-57-ST, by a small margin. Both rate poor for machinability — 25/100 against 18/100 for V-57 STA-900; for welding the order is V-57-ST first (good, 55/100) then V-57 STA-900 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in V-57-ST and V-57 STA-900 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.