S82013-CD and S82013-SA are two conditions of the same stainless steel grade, S82013: CD (cold drawn) versus SA (solution Annealed). The chemistry is identical, so every difference below comes from the condition. S82013-CD is the stronger of the two: yield strength 720 MPa (104 ksi) against 540 MPa (78.3 ksi) for S82013-SA, about 33% more; tensile strength follows at 880 MPa (128 ksi) vs 730 MPa (106 ksi). In exchange, S82013-SA is the more ductile: elongation 30% versus 18% for S82013-CD, and S82013-CD is harder (285 HB vs 230 HB). S82013-SA runs hotter in service (280°C vs 250°C continuous). On the shop floor, S82013-SA welds better (65 vs 55 out of 100).

S82013-CDChoose it when strength drives the design.

S82013-SAChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S82013-CD vs S82013-SA: properties

S82013-CDS82013-SA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

880 MPa128 ksi
730 MPa106 ksi

Yield Strength (0.2% offset)

720 MPa104 ksi
540 MPa78.3 ksi

Elongation at Break

18%
30%

Reduction in Area

45%
55%

Compressive Strength

740 MPa107 ksi
550 MPa79.8 ksi

Shear Strength

540 MPa78.3 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
350 MPa50.8 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
130 MPa·√m118 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
130 J95.9 ft·lbf

Hardness, Brinell

285 HB
230 HB

Hardness, Rockwell C

29 HRC
20 HRC

Hardness, Vickers

300 HV
240 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3 · Hardness, Rockwell B 98 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
280°C536 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

56 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
30%

Weldability

55 / 100
65 / 100

Formability (cold)

30 / 100
55 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleS82013

S82013-CD vs S82013-SA — frequently asked

Is S82013-CD stronger than S82013-SA?

Yes. S82013-CD has a typical yield strength of 720 MPa (104 ksi) against 540 MPa (78.3 ksi) for S82013-SA — about 33% more. Tensile strength is 880 MPa (128 ksi) vs 730 MPa (106 ksi).

Which condition does FabDigit quote by default, CD or SA?

SA is the default S82013 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S82013-CD or S82013-SA?

S82013-CD, by a small margin. Both rate fair for machinability — 40/100 against 35/100 for S82013-SA; for welding the order is S82013-SA first (good, 65/100) then S82013-CD (good, 55/100).