FabDigitFabDigit

Stainless Steel S35140-CD vs S35140 CR-1/4H

Stainless Steel · S35140 temper comparison

S35140-CD and S35140 CR-1/4H are two conditions of the same stainless steel grade, S35140: CD (cold drawn) versus CR-1/4H (cold Rolled 1/4 Hard). The chemistry is identical, so every difference below comes from the condition. S35140-CD is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 520 MPa (75.4 ksi) for S35140 CR-1/4H, about 6% more. In exchange, S35140 CR-1/4H is the more ductile: elongation 25% versus 22% for S35140-CD, and S35140-CD is harder (240 HB vs 215 HB). S35140-CD runs hotter in service (1,000°C vs 425°C continuous).

S35140-CDChoose it when strength drives the design, or when the part sees heat.

S35140 CR-1/4HChoose it when the part is bent, formed or impact-loaded.

S35140-CD vs S35140 CR-1/4H: properties

S35140-CDS35140 CR-1/4H

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Yield Strength (0.2% offset)

550 MPa79.8 ksi
520 MPa75.4 ksi

Elongation at Break

22%
25%

Reduction in Area

48%
45%

Shear Strength

470 MPa68.2 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
305 MPa44.2 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

240 HB
215 HB

Hardness, Rockwell B

99 HRB
96 HRB

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 76 GPa11 Msi · Bulk Modulus 150 GPa21.8 Msi · Poisson's Ratio 0.3 · Tensile Strength (Ultimate) 760 MPa110 ksi

Physical

Density and transition temperatures.

Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,350°C2,462 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

1,000°C1,832 °F
425°C797 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.5 µm/m·K8.1 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 76 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
33%

Weldability

70 / 100
68 / 100

Formability (cold)

40 / 100
55 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 6.2 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleS35140

S35140-CD vs S35140 CR-1/4H — frequently asked

Is S35140-CD stronger than S35140 CR-1/4H?

Yes. S35140-CD has a typical yield strength of 550 MPa (79.8 ksi) against 520 MPa (75.4 ksi) for S35140 CR-1/4H — about 6% more. Tensile strength is 760 MPa (110 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, CD or CR-1/4H?

Annealed is the default S35140 condition in the FabDigit quote flow (neither CD nor CR-1/4H). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose S35140-CD over S35140 CR-1/4H?

Pick S35140-CD when strength drives the design, or when the part sees heat. Pick S35140 CR-1/4H when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S35140-CD and S35140 CR-1/4H side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.