FabDigitFabDigit

Stainless Steel S35140-AW vs S35140-CD

Stainless Steel · S35140 temper comparison

S35140-AW and S35140-CD are two conditions of the same stainless steel grade, S35140: AW (as-welded deposit) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. S35140-CD is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 300 MPa (43.5 ksi) for S35140-AW, about 83% more; tensile strength follows at 760 MPa (110 ksi) vs 590 MPa (85.6 ksi). In exchange, S35140-AW is the more ductile: elongation 30% versus 22% for S35140-CD, and S35140-CD is harder (240 HB vs 185 HB).

S35140-AWChoose it when the part is bent, formed or impact-loaded.

S35140-CDChoose it when strength drives the design.

S35140-AW vs S35140-CD: properties

S35140-AWS35140-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

590 MPa85.6 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
550 MPa79.8 ksi

Elongation at Break

30%
22%

Reduction in Area

40%
48%

Shear Strength

400 MPa58 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
320 MPa46.4 ksi

Charpy V-Notch Impact (RT)

75 J55.3 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

185 HB
240 HB

Hardness, Rockwell B

89 HRB
99 HRB

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 76 GPa11 Msi · Bulk Modulus 150 GPa21.8 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,350°C2,462 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

980°C1,796 °F
1,000°C1,832 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.5 µm/m·K8.1 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
76 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Weldability

72 / 100
70 / 100

Formability (cold)

45 / 100
40 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 6.2 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleS35140

S35140-AW vs S35140-CD — frequently asked

Is S35140-CD stronger than S35140-AW?

Yes. S35140-CD has a typical yield strength of 550 MPa (79.8 ksi) against 300 MPa (43.5 ksi) for S35140-AW — about 83% more. Tensile strength is 760 MPa (110 ksi) vs 590 MPa (85.6 ksi).

Which condition does FabDigit quote by default, AW or CD?

Annealed is the default S35140 condition in the FabDigit quote flow (neither AW nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S35140-AW or S35140-CD?

S35140-CD. Its machinability rates fair (35/100) against poor (30/100) for S35140-AW.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S35140-AW and S35140-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.