Stainless Steel · PH14-8Mo temper comparison

PH14-8Mo-A and PH14-8Mo-CH900 are two conditions of the same stainless steel grade, PH14-8Mo: A (solution annealed) versus CH900 (cold rolled (≈60 %) from Condition A + age 482 °C). The chemistry is identical, so every difference below comes from the condition. PH14-8Mo-CH900 is the stronger of the two: yield strength 1,720 MPa (249 ksi) against 415 MPa (60.2 ksi) for PH14-8Mo-A, about 4.1 times as much; tensile strength follows at 1,790 MPa (260 ksi) vs 895 MPa (130 ksi). In exchange, PH14-8Mo-A is the more ductile: elongation 25% versus 2% for PH14-8Mo-CH900, and PH14-8Mo-CH900 is harder (49 HRC vs 25 HRC). On the shop floor, PH14-8Mo-A machines more easily (fair vs poor) and PH14-8Mo-A welds better (good vs poor).

PH14-8Mo-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

PH14-8Mo-CH900Choose it when strength drives the design.

PH14-8Mo-A vs PH14-8Mo-CH900: properties

PH14-8Mo-APH14-8Mo-CH900

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

895 MPa130 ksi
1,790 MPa260 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
1,720 MPa249 ksi

Elongation at Break

25%
2%

Shear Strength

570 MPa82.7 ksi
1,050 MPa152 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
740 MPa107 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
8 J5.9 ft·lbf

Hardness, Rockwell C

25 HRC
49 HRC

Hardness, Vickers

260 HV
510 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Reduction in Area 60% · Hardness, Rockwell B 95 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15.9 W/m·K9.2 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
20%

Weldability

60 / 100
25 / 100

Formability (cold)

70 / 100
8 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scalePH14-8Mo

PH14-8Mo-A vs PH14-8Mo-CH900 — frequently asked

Is PH14-8Mo-CH900 stronger than PH14-8Mo-A?

Yes. PH14-8Mo-CH900 has a typical yield strength of 1,720 MPa (249 ksi) against 415 MPa (60.2 ksi) for PH14-8Mo-A — about 4.1 times as much. Tensile strength is 1,790 MPa (260 ksi) vs 895 MPa (130 ksi).

Which condition does FabDigit quote by default, A or CH900?

A is the default PH14-8Mo condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, PH14-8Mo-A or PH14-8Mo-CH900?

PH14-8Mo-A. Its machinability rates fair (40/100) against poor (20/100) for PH14-8Mo-CH900; for welding the order is PH14-8Mo-A first (good, 60/100) then PH14-8Mo-CH900 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in PH14-8Mo-A and PH14-8Mo-CH900 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.