FabDigitFabDigit

Stainless Steel PH 13-8 Mo Condition A vs PH 13-8 Mo-H1150

Stainless Steel · PH 13-8 Mo temper comparison

PH 13-8 Mo Condition A and PH 13-8 Mo-H1150 are two conditions of the same stainless steel grade, PH 13-8 Mo: Condition A (solution annealed) versus H1150 (overaged 621 °C (1150 °F) for 4 h, maximum toughness). The chemistry is identical, so every difference below comes from the condition. PH 13-8 Mo-H1150 is the stronger of the two: yield strength 965 MPa (140 ksi) against 800 MPa (116 ksi) for PH 13-8 Mo Condition A, about 21% more; tensile strength follows at 1,070 MPa (155 ksi) vs 1,000 MPa (145 ksi). PH 13-8 Mo-H1150 is the more ductile: elongation 18% versus 14% for PH 13-8 Mo Condition A. PH 13-8 Mo-H1150 runs hotter in service (510°C vs 315°C continuous).

PH 13-8 Mo-H1150Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

PH 13-8 Mo Condition A vs PH 13-8 Mo-H1150: properties

PH 13-8 Mo Condition APH 13-8 Mo-H1150

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,000 MPa145 ksi
1,070 MPa155 ksi

Yield Strength (0.2% offset)

800 MPa116 ksi
965 MPa140 ksi

Elongation at Break

14%
18%

Reduction in Area

60%
62%

Shear Strength

640 MPa92.8 ksi
670 MPa97.2 ksi

Fatigue Strength (Endurance Limit)

480 MPa69.6 ksi
540 MPa78.3 ksi

Charpy V-Notch Impact (RT)

22 J16.2 ft·lbf
75 J55.3 ft·lbf

Hardness, Brinell

320 HB
310 HB

Same in both: Elastic (Young's) Modulus 203 GPa29.4 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 155 GPa22.5 Msi · Poisson's Ratio 0.28 · Compressive Strength 830 MPa120 ksi · Hardness, Rockwell C 33 HRC

Physical

Density and transition temperatures.

Same in both: Density 7.76 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

315°C599 °F
510°C950 °F

Same in both: Thermal Conductivity 14 W/m·K8.1 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.6 µm/m·K5.9 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.02×10⁻⁶ Ω·m40.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 32 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 60 / 100 · Formability (cold) 40 / 100 · Brazeability / Solderability 50 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 110 L/kg13.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scalePH 13-8 Mo

PH 13-8 Mo Condition A vs PH 13-8 Mo-H1150 — frequently asked

Is PH 13-8 Mo-H1150 stronger than PH 13-8 Mo Condition A?

Yes. PH 13-8 Mo-H1150 has a typical yield strength of 965 MPa (140 ksi) against 800 MPa (116 ksi) for PH 13-8 Mo Condition A — about 21% more. Tensile strength is 1,070 MPa (155 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, Condition A or H1150?

Condition A is the default PH 13-8 Mo condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose PH 13-8 Mo Condition A over PH 13-8 Mo-H1150?

Pick PH 13-8 Mo-H1150 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in PH 13-8 Mo Condition A and PH 13-8 Mo-H1150 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.