FabDigitFabDigit

Stainless Steel Nitronic 50 Annealed vs Nitronic 50 Hot Rolled

Stainless Steel · Nitronic 50 temper comparison

Nitronic 50 Annealed and Nitronic 50 Hot Rolled are two conditions of the same stainless steel grade, Nitronic 50: Annealed versus Hot Rolled. The chemistry is identical, so every difference below comes from the condition. Nitronic 50 Hot Rolled is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 430 MPa (62.4 ksi) for Nitronic 50 Annealed, about 16% more; tensile strength follows at 830 MPa (120 ksi) vs 780 MPa (113 ksi). In exchange, Nitronic 50 Annealed is the more ductile: elongation 45% versus 38% for Nitronic 50 Hot Rolled, and Nitronic 50 Hot Rolled is harder (240 HB vs 210 HB).

Nitronic 50 AnnealedChoose it when the part is bent, formed or impact-loaded.

Nitronic 50 Hot RolledChoose it when strength drives the design.

Nitronic 50 Annealed vs Nitronic 50 Hot Rolled: properties

Nitronic 50 AnnealedNitronic 50 Hot Rolled

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
830 MPa120 ksi

Yield Strength (0.2% offset)

430 MPa62.4 ksi
500 MPa72.5 ksi

Elongation at Break

45%
38%

Reduction in Area

60%
55%

Shear Strength

520 MPa75.4 ksi
540 MPa78.3 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
180 MPa·√m164 ksi·√in

Charpy V-Notch Impact (RT)

190 J140 ft·lbf
160 J118 ft·lbf

Hardness, Brinell

210 HB
240 HB

Hardness, Rockwell B

94 HRB
99 HRB

Hardness, Vickers

228 HV
252 HV

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 76 GPa11 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.88 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,343°C2,449 °F · Liquidus Temperature 1,399°C2,550 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 12.5 W/m·K7.2 BTU/hr·ft·°F · Specific Heat Capacity 502 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.3 µm/m·K8.5 µin/in·°F · Max Service Temperature (continuous) 800°C1,472 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.4 % IACS · Electrical Resistivity 7.2×10⁻⁷ Ω·m28.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
74 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
22%

Weldability

70 / 100
68 / 100

Formability (cold)

57 / 100
48 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleNitronic 50

Nitronic 50 Annealed vs Nitronic 50 Hot Rolled — frequently asked

Is Nitronic 50 Hot Rolled stronger than Nitronic 50 Annealed?

Yes. Nitronic 50 Hot Rolled has a typical yield strength of 500 MPa (72.5 ksi) against 430 MPa (62.4 ksi) for Nitronic 50 Annealed — about 16% more. Tensile strength is 830 MPa (120 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, Annealed or Hot Rolled?

Solution Annealed is the default Nitronic 50 condition in the FabDigit quote flow (neither Annealed nor Hot Rolled). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Nitronic 50 Annealed over Nitronic 50 Hot Rolled?

Pick Nitronic 50 Annealed when the part is bent, formed or impact-loaded. Pick Nitronic 50 Hot Rolled when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Nitronic 50 Annealed and Nitronic 50 Hot Rolled side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.