FabDigitFabDigit

Stainless Steel Alloy 465-A vs Alloy 465-H1025

Stainless Steel · Alloy 465 temper comparison

Alloy 465-A and Alloy 465-H1025 are two conditions of the same stainless steel grade, Alloy 465: A (solution annealed) versus H1025 (aged 552 °C (1025 °F) for 4 h). The chemistry is identical, so every difference below comes from the condition. Alloy 465-H1025 is the stronger of the two: yield strength 1,480 MPa (215 ksi) against 760 MPa (110 ksi) for Alloy 465-A, about 95% more; tensile strength follows at 1,550 MPa (225 ksi) vs 1,000 MPa (145 ksi). In exchange, Alloy 465-A is the more ductile: elongation 18% versus 15% for Alloy 465-H1025, and Alloy 465-H1025 is harder (410 HB vs 302 HB). Alloy 465-H1025 runs hotter in service (420°C vs 300°C continuous). On the shop floor, Alloy 465-A machines more easily (fair vs poor).

Alloy 465-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

Alloy 465-H1025Choose it when strength drives the design, or when the part sees heat.

Alloy 465-A vs Alloy 465-H1025: properties

Alloy 465-AAlloy 465-H1025

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,000 MPa145 ksi
1,550 MPa225 ksi

Yield Strength (0.2% offset)

760 MPa110 ksi
1,480 MPa215 ksi

Elongation at Break

18%
15%

Reduction in Area

68%
62%

Shear Strength

985 MPa143 ksi
930 MPa135 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
700 MPa102 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
121 MPa·√m110 ksi·√in

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
47 J34.7 ft·lbf

Hardness, Brinell

302 HB
410 HB

Hardness, Rockwell C

32 HRC
44 HRC

Hardness, Vickers

318 HV
435 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 1,620 MPa235 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
420°C788 °F

Same in both: Thermal Conductivity 16 W/m·K9.2 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

52 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
32%

Weldability

65 / 100
60 / 100

Formability (cold)

40 / 100
14 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 40 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 80 MJ/kg34,394 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleAlloy 465

Alloy 465-A vs Alloy 465-H1025 — frequently asked

Is Alloy 465-H1025 stronger than Alloy 465-A?

Yes. Alloy 465-H1025 has a typical yield strength of 1,480 MPa (215 ksi) against 760 MPa (110 ksi) for Alloy 465-A — about 95% more. Tensile strength is 1,550 MPa (225 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, A or H1025?

H1000 is the default Alloy 465 condition in the FabDigit quote flow (neither A nor H1025). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Alloy 465-A or Alloy 465-H1025?

Alloy 465-A. Its machinability rates fair (40/100) against poor (30/100) for Alloy 465-H1025; for welding the order is Alloy 465-A first (good, 65/100) then Alloy 465-H1025 (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Alloy 465-A and Alloy 465-H1025 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.