FabDigitFabDigit

Stainless Steel A286 Annealed vs A286 Solution Annealed

Stainless Steel · A286 temper comparison

A286 Annealed and A286 Solution Annealed are two conditions of the same stainless steel grade, A286: Annealed versus Solution Annealed. The chemistry is identical, so every difference below comes from the condition. A286 Solution Annealed is the stronger of the two: yield strength 310 MPa (45 ksi) against 260 MPa (37.7 ksi) for A286 Annealed, about 19% more; tensile strength follows at 690 MPa (100 ksi) vs 620 MPa (89.9 ksi). In exchange, A286 Annealed is the more ductile: elongation 45% versus 40% for A286 Solution Annealed, and A286 Solution Annealed is harder (170 HB vs 155 HB).

A286 AnnealedChoose it when the part is bent, formed or impact-loaded.

A286 Solution AnnealedChoose it when strength drives the design.

A286 Annealed vs A286 Solution Annealed: properties

A286 AnnealedA286 Solution Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
310 MPa45 ksi

Elongation at Break

45%
40%

Reduction in Area

60%
55%

Shear Strength

390 MPa56.6 ksi
430 MPa62.4 ksi

Hardness, Brinell

155 HB
170 HB

Hardness, Rockwell B

84 HRB
88 HRB

Same in both: Elastic (Young's) Modulus 201 GPa29.2 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 168 GPa24.4 Msi · Poisson's Ratio 0.31 · Fatigue Strength (Endurance Limit) 300 MPa43.5 ksi · Charpy V-Notch Impact (RT) 120 J88.5 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.92 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

600°C1,112 °F
650°C1,202 °F

Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.4 µm/m·K9.1 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.9 % IACS · Electrical Resistivity 9.1×10⁻⁷ Ω·m35.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
22%

Formability (cold)

65 / 100
60 / 100

Same in both: Weldability 55 / 100 · Castability 35 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 100 MJ/kg42,992 BTU/lb · Embodied Carbon (primary production) 6.8 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleA286

A286 Annealed vs A286 Solution Annealed — frequently asked

Is A286 Solution Annealed stronger than A286 Annealed?

Yes. A286 Solution Annealed has a typical yield strength of 310 MPa (45 ksi) against 260 MPa (37.7 ksi) for A286 Annealed — about 19% more. Tensile strength is 690 MPa (100 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, Annealed or Solution Annealed?

Solution Annealed is the default A286 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A286 Annealed over A286 Solution Annealed?

Pick A286 Annealed when the part is bent, formed or impact-loaded. Pick A286 Solution Annealed when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A286 Annealed and A286 Solution Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.